Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Engineering

Pipe Element (PIPE)

  • Last UpdatedOct 24, 2024
  • 2 minute read

Piping Major Items Element

Primary Element

Description

The PIPE is an administrative owner of one or more two-ended BRANCHes. Usually a PIPE will include a principle BRANCH routed between two NOZZLES, with subsidiary BRANCHes for control loops, bypasses to spare pumps and so on. The PIPE contains functional attributes of three types:

Those which are used directly from the PIPE element (by modules such as ISODRAFT) as a collective attribute for all the BRANCHes in the PIPE, for example: Pipe Spec (PSPE).

Those which have no direct significance at PIPE level, but which are cascaded downwards to member BRANCHes (or even Components) where they perform a particular function, for example: TEMPERATURE - only used by Branch for insulation, stressing and so on.

Information attributes that can only be reported on, for example: BUILT.

Attributes

Name

Name of the element

Description

Description of the element

Function

Function

Purpose

Description code word

Built

Built/Unbuilt flag

Shop

Shop/Site flag

Isohidden

Isohidden flag

Bore

Bore

Temperature

Temperature

Pressure

Pressure

TPressure

TestPressure

Pspec

Pipe specification

Ispec

Insulation spec reference

Tspec

Tracing spec reference

Matref

Material reference

Fluref

Fluid reference

Casref

Case reference

Ccentre

Cost center

Cclass

Cost class

Linetype

Line type

Erection

Erection class

Rev

Pipe Revision number

Safclass

Safety class

Duty

Duty

Dscode

Design code

Ptspec

Paint specification

Inschedule

Inspection schedule

Skey

Symbol key

Lissue

True if drawing has been issued

Wmaximum

Maximum weld number in current spool drawing

Pmaximum

Maximum part number in current spool drawing

Smaximum

Maximum spool number in current spool drawing

Jmaximum

Maximum joint number in current spool drawing

Drrf

Old spooler drawing reference

Cdrg

Isodraft Compipe: Drawing number

Cnumber

Isodraft Compipe: Line number

Carea

Isodraft Compipe: Area

Splprefix

Spool number prefix

Orrf

Origin reference (for templates)

BendMacReference

Bending Machine reference

Uuidia

Universally unique identifier

Rlstored

Array of ROUTER saved rules

Deldsg

Delivery Designation flag

Farea

Construction area

Fpline

Process line number

Fdrawing

Isometric drawing number

Frevision

Isometric drawing revision

Frdrawing

Reference drawings

Fstatus

Fstatus

PLANU

Planning Unit

JNTC

Joint Code

WLDC

Weld Code

HEATT

Heat Treatment

Mdsysf

Reference Array of Model and Design Elements

Inprtref

Inside paint reference

Ouprtref

Outside paint reference

Sloreference

Pipe slope reference

Conveyor Element (CONVEYOR)

Zone Element (ZONE)

Branch Element (BRANCH)

Pipe Piece List Element (PPLIST)

Pipe Spool List Element (PSLIST)

Restraint Element (RESTRAINT)

Text Element (TEXT)

In This Topic