AVEVA™ Engineering

Checking Locations are Aligned

  • Last UpdatedFeb 02, 2022
  • 2 minute read

A simple check to make sure that locations are aligned is to run a macro which captures the latest session number of each secondary database as compared to the latest session of the Primary database.

Note:
Such a macro could use the Q REMOTE command to query the remote location (Q REMOTE <loc> <dbname> LASTSESSION). The session number can be extracted from the query result.
Q REMOTE ABC MYTEAM/DESI LASTSESSION
Q REMOTE ABC MYTEAM/DESI FILEDETAILS

Assuming it is run when there are no users on the project then the session numbers at all the locations should be identical, however if the Primary db is being used it is likely that the Primary session number will be slightly higher than the Secondary databases. As the intention is that Global runs while users are continuing to work this will be the most common scenario.

If for some reason the Secondary database is higher than the Primary, detailed investigation will be required to realign that database. An example of the type of output from such a macro follows:

DBnumber

DBname

Session_SAT1

Session_SAT2

Session_SAT3

Session_HUB

2001

SAT1PIPING/UNITA

P 1134

S 1128

S 1128

S 1128

2000

SAT1PIPING/UNITB

P 684

S 679

S 679

S 679

2002

SAT1PIPING/UNITC

P 106

S 106

S 107

S 106

2003

SAT1PIPING/UNITD

P 758

S 742

S 692

S 742

2004

SAT1PIPING/UNITE

P 533

S 517

S 467

S 517

2457

SAT3PIPING/UNITA

S 1164

S 1164

P 1169

S 1164

2451

SAT3PIPING/UNITB

S 814

S 793

P 849

S 814

2432

SAT3PIPING/UNITC

S 131

S 131

P 133

S 131

2431

SAT3PIPING/UNITD

S 451

S 451

P 453

S 451

2100

HUBPIPING/UNITA

S 1148

S 1148

S 1148

P 1175

2102

HUBPIPING/UNITB

S 212

S 212

S 212

P 213

2104

HUBPIPING/UNITC

S 231

S 231

S 231

P 234

2355

SAT2PIPING/UNITA

S 560

P 562

S 560

S 560

2353

SAT2PIPING/UNITB

S 288

P 328

S 288

S 324

2351

SAT2PIPING/UNITC

S 513

P 578

S 484

S 541

2351

SAT2PIPING/UNITD

S 79

P 101

S 79

S 79

2343

SAT2PIPING/UNITE

S 174

P 176

S 174

S 174

Related Links
TitleResults for “How to create a CRG?”Also Available in