Attribute Category: Cabling

  • Last UpdatedOct 24, 2024
  • 3 minute read

Attribute Name

Data Type

Qualifier

Description

ACLIST

element(500)

Arriving cables to attached point

ATCONN

element(500)

List of elements connected to attachment

AYDIR

dir

Arrive Y axis direction

BRLIST

real(500)

Bend radii of a cable

CABBOX

real(6)

Calculated box volume in world coordinates

CABGAP

real

cable gap on cabletray as multiple of OUTD

CABINT

string(120)

cable interference class

CABLAY(OUT)

real

Defines laying method for cables inside the branch. Attribute on %CWAY has no effect on functionality – it's used only to cascading down to CWBRAN during creation of new CWBRAN.

CBACXR

real

integer

Accumulated cables xarea at route node

CBCOG

pos

Cable center of gravity

CBCULE

real

Cut Length of cable

CBFRLE

real(20)

Free Length of cable

CBGELE

real

Geometric Length of cable

CBNUCW

element(500)

Cables at a point on a cableway

CBPREF

element(500)

References to POINTR forming route of a cable

CBRNLS

element(500)

List of route nodes that cable passes

CBRRLS

element(500)

List of route nodes and rattas that cable passes

CBRWGL

real

Raw Geometric Length of cable

CBSTT

string(10)

Cable status text

CBTOLE

real

Total Length of Cable

CBWEIG

real

Cable weight

CENRAD

Returns the center radius of CWBRAN volume at this particular point

CENRADIUS

real

Centerline Radius

CFCHE

logical

Fill level check

CFILL

real

Fill level at route node

CLIST

element(500)

integer

All cables attached to route node

CMAXF

real

Calculate maximum fill level on cway

CMINF

real

Calculate minimum fill level on cway

CONATS

element(500)

List of attachment connected to attachment

CONBRA

element(500)

List of branches connected to branch

CONNE

logical

Segment end connection flag

CONNS

logical

Segment start connection flag

CONSIS

logical

Position consistency

CONTRA

element(500)

List of trays connected to branch

CWJBLS

element(500)

Cableway branches and junction boxes list

CWJUSL

word

Cable Way Justification Line

CWLIST

element(500)

All cableways attached to route node

CWPPJB

element(500)

Cableway branches and pull pits and junction boxes list

CWPPLS

element(500)

Cableway branches and pull pits list

DEPREF

element(500)

List of elements connected to branch tail

DFBRAD(IUS)

real

Return value of radius at POINTR used to select correct specification component:

Always inside radius at bends

Inside or outside radius at risers *(depending whether riser is Inside/Outside)

ELCXRF

element(500)

Return reference from CABLE element to ELCONN element

ENBINF

pos

integer

End bend information

FCENTRE

pos

Center of fillet arc

FEND

pos

Fillet arc position

FILREF

element(500)

Sorted references to attachment points with ascending order of fill level greater then 0

FLEVEL

real

integer

Fill level at route node

FMID

pos

Middle point of fillet arc

FSTART

pos

Fillet start position

HDCONN

element(500)

List of elements connected to branch head

HDREF

element(500)

List of attachment connected to attachment

INSLEN

real(200)

Installation length

INSMETHOD

string(240)

Getting installation method lengths. The output is a textual array describing length of installation method along the cable. Size of the array depends on how many different installation methods are applied along the cable route.

INSRAD

Returns the smallest radius of CWBRAN at this particular point

INSRADIUS

real

Inside Radius

INSTLV(EL)

string(240)

Getting installation level and dressing. The output is a textual array of 5 elements as follows:

Free Route, <length>

length of the part of the cable that is routed outside branch

Underground Dressed, <length>

… inside *underground dressed branch

Underground Not Dressed, <length>

...inside underground undressed branch

Above Ground Dressed, <length>

...inside above ground dressed branch

Above Ground Not Dressed

...inside above ground dressed branch

*underground – is determined by attribute UNDERG queried on the branch

INVRAD(IUS)

logical

Returns true if cable uses a radius smaller than minimum radius for it's specification (see property MINBEN)

JBLIST

element(500)

Junction boxes list

LALCAB

element(500)

List arriving leaving cables on attached point

LAYMOT

string(100)

integer

Layout mode text

LYDIR

dir

Leave Y axis direction on point

MINFIL

real

Min Fill level on Cableway and Cabletray components

NPLIST

element(500)

All NATPs attached to route node

NUMCOR

integer

Number of cores in a cable

OUTRAD

Returns the biggest radius of CWBRAN at this particular point

OUTRADIUS

real

Outside Radius

OVCWIDTH

real

Overall cables width

PRFELE

element

Cableway profile element

PRFOBS

integer

Cableway profile obstructions

PULLLS

element(500)

Pull pit list

RADI

real

Obtains the radius of a cable at this particular point

RCONAT

element(500)

element

List of valid connected route attachments

RILIST

element(500)

Route information list

RMINIMUM

real

Scans all the routing points the cable is routed through and returns the minimal radius of the cable

RNODEL

element(500)

word

Rnode list

ROUHEIGHT

real

Routing Height

ROUWIDTH

real

Routing Width

STBINF

pos

integer

Start bend information

STRJUS

word

Cable Way Justification Line

TLCONN

element(500)

List of elements connected to branch tail

TLREF

element(500)

List of attachment connected to attachment

TXAREA

real

Total Cableway X-area

VRADI

real

Cableway radius