When Integrator builds Cable in the 3D model, the following actions are carried out.

  • The names of an appropriate SITE and ZONE are determined from the rules.

  • A CABLE is created in the appropriate ZONE and named in accordance with the rules.

  • Start and End references are set in accordance with schematic connectivity if the connecting elements exist in 3D. Connections can be direct to equipment using the ELCXRF attribute or to ELCONNs.

  • Attribute values can be set on CABLES in accordance with the rules.

  • The schematic and 3D elements are linked.

Integrator does not create CORE elements below 3D cables, even if the schematic cable owns schematic cores. If needed, schematic core data can be referenced from the 3D model via the owning cable's SCHLNK attribute.

Integrator builds the individual cables for a Schematic Multi-Cable (SCMCAB). There is no 3D model equivalent of SCMCAB.