Attribute Category: Piping
- Last UpdatedOct 24, 2024
- 1 minute read
|
Attribute Name |
Data Type |
Qualifier |
Description |
|
ARRI |
integer |
Arrive Ppoint |
|
|
ATCLL |
real |
Centerline length of arrive implied tube |
|
|
ATLE |
real |
Length of arrive implied tube |
|
|
CEND |
string |
Connection at other end of CREF (HEAD or TAIL) |
|
|
FITLEN |
real |
Length of branch fitting |
|
|
GRDE |
real |
Gradient of implied tube. Gradient is the vertical rise(fall) divided by the horizontal distance. |
|
|
HDIR |
dir |
Head direction |
|
|
INLEN |
real |
Insulation length |
|
|
INTHK |
real |
Insulation thickness |
|
|
ITLE |
real |
Length of implied tube |
|
|
ITPS |
pos |
Position of implied tube |
|
|
LEAV |
integer |
Leave Ppoint |
|
|
LTCLL |
real |
Centerline length of leave implied tube |
|
|
LTLE |
real |
Length of leave implied tube |
|
|
MTBE |
element |
Material tube start. The first component, excluding ATTSs, for whom the LOFF is invalid or false |
|
|
MTCL |
real |
Material tube centerline length. |
|
|
MTEN |
element |
Material tube end. The first component, excluding ATTSs, for whom the LOFF is invalid or false |
|
|
MTLE |
real |
Material tube length for TUBI. Includes preceding bend length if bend is offline. |
|
|
MTOL |
string(1000) |
Material List Length |
|
|
MTOQ |
string(1000) |
Material take off quantity |
|
|
PCREF |
integer(4) |
integer |
Ppoint and ref of connected piping component |
|
POCK |
word |
Is a branch component in a pocket |
|
|
ROBRRU |
element(500) |
Router Rules applying to a piping element or members |
|
|
STAP |
real |
Length of arrive straight tube |
|
|
STLE |
real |
Length of leave straight tube |
|
|
TDIR |
dir |
Tail direction |
|
|
TEXIST |
logical |
True if component has TUBI. Always true for offline bends. |
|
|
TGEOM |
logical |
True if component has TUBI geometry |
|
|
TRLEN |
real |
Tracing length |