All the information which the Data integrity Checker (DICE) can determine about a Database (DB) before starting its detailed checks is presented in the report header.

The format of the header is as follows:

PDMS Admin Mk11.6.0 (WINDOWS-NT 5.0) (9 Sep 2004 : 02:37)

(c) Copyright 1974 to 2004 AVEVA Solutions Limited

DEVELOPMENT test version - NOT for production use

Issued to AVEVA Solutions Ltd - Complete License

*****************************

* DATABASE INTEGRITY REPORT *

*****************************

Date 10 Sep 2004 Time 11:20

Project ABC

Database ADMIN/PADD

Filename

/%ABC000%/abc013

DB number

7203

Extract number

1

DB type

PADD

DB size

299 Pages

(0.612 Million bytes)

Maximum size

2000 Million Pages

DB is 0% full

Page size

2048 bytes

Last session Number: 3

Last Session Date: 14:40 17 Jan 2003

Last Session User: lbr

Last Session Description: Db modified

Options requested

STATISTICS OFF

CHECK CLAIM LIST

FULL CHECK

DICE Banner. This is repeated at the beginning of each report, in addition to its display when first entering the module. It confirms the particular version of DICE which produced the report.

Date and Time. The date and time at which the check was started for that particular DB or file.

Project. The three-character project code.

Database. The name by which the DB is known within the project.

Filename. The name of the external file containing the DB.

DB number. The DB identification number, as it appears in the output from the LIST FILES command.

DB type. Design, Catalogue, Drawing etc.

DB size. The amount of space, in pages and megabytes, currently used by the DB in its file. Also shown are the maximum size (in pages) and the percentage of space filled.

Note:
If the database is more than 90% full, the space filled is output as a warning.

Page size. The number of bytes per file page.

Options requested. Confirms the settings of the checking options:

  • STATISTICS OFF or BRIEF STATISTICS or STATISTICS ON

  • CHECK EXTERNAL REFERENCES

  • LIST REFERENCED DATABASES

  • BRIEF CHECK or FULL CHECK

Finally the report summary and the error report will be given, as described in the following sections.