Project Defaults have a name and a single setting, if any are omitted the standard default values described below will be used.

|
Real Tolerance |
This is the value that is used to compare real number attributes. Two attribute values within this tolerance are deemed to be equal. If no Real Tolerance value is specified the built-in default is 0.00001. |
|
Distance Tolerance |
This is the value that is used to compare distance attributes. Two attribute values within this tolerance are deemed to be equal. If no Distance Tolerance value is specified the built-in default is 0.01. |
|
Distance and Bore Units |
These determine which units are used for distance and bore values embedded within rules. The options are mm or inch. |
|
Can Create Site |
This determines whether a SITE may be automatically created during Build operations if no suitable SITE already exists (as specified by the project build rules). The built-in default setting is false. |
|
Can Create Zone |
This determines whether a ZONE may be automatically created during Build operations if no suitable ZONE already exists (as specified by the project build rules). The built-in default setting is false. |
|
Compare Flanges, Couplings and Unions |
By default, flanges, couplings and unions that appear only in 3D are treated as insignificant for compare. Those that appear on the P&ID will always be compared. Set the appropriate flags true to get all instances of these items in 3D compared. |
|
Default Configurations, Colours Category and Rule Sets |
These determine which settings are used if an appropriate configuration has not been defined or has not been selected. |