Configurations
- Last UpdatedNov 28, 2024
- 2 minute read
Configurations are defined by the administrator to cover the range of uses intended for their end users. In the out-of-the-box project configuration file; a basic setup to check for matching tagged items and pipe specifications may be defined for early use on a project, along with a full setup and piping check to be used on mature data. Each Configuration combines a set of compare colours, a comparison category and a rule set.

To add a new configuration, right click on Configurations in the Integrator Project Configuration Explorer and select Insert.

|
Name |
Enter a name for the new configuration. |
|
Description |
Enter an optional description of the configuration. |
|
Compare Colours |
The default set of colours |
|
Category |
The default category. |
|
Rule Set |
A rule set has to be defined or imported one from another configuration file in order to complete the selection. |
|
Compare Options |
Ignore Accepted Differences reports each difference as if it had not been accepted. |
|
Reports unpositioned elements to warn when piping elements have been built but not yet positioned and orientated. |
|
|
Strictly limit compare to selected elements provides a faster report (recommended). If unchecked, Integrator may take longer to complete the report and may include additional pipelines. This can occur when matched pipes also partially match additional pipelines. |
|
|
Compare Lines/Pipes without member hierarchies to compare in Line List mode. |
|
|
Whole Diagram Compare |
Sets which main types will be included in the report for a Compare Diagram operation. |