Colour Coded Integrator Report
- Last UpdatedNov 28, 2024
- 3 minute read
The Integrator report uses traffic light icons to represent a visual representation of the discrepancies found during the comparison, the colours used as the default. To amend the colours used, refer to the system administrator.

The Details tab is populated with the filtered schematic and 3D information of the whole comparison.

Use the Integrator Comments window to view the comments and attribute details for the selected schematic or 3D element.

|
. |
OK |
Displayed when the elements are matched and there are no differences to be reported. |
|
|
Accepted Differences |
Displayed when the elements are linked but have defined acceptable differences. |
|
|
Problem with Model |
Displayed when there is an issue with either the schematic or 3D model that affects Integrator's ability to make a meaningful comparison. |
|
|
Attribute Difference |
Displayed when there are one or more differences in attributes of the matched elements, for example: connection error, sequence difference or specification difference. |
|
|
Not Matched |
Displayed when an element on the diagram does not have a matching element in the 3D model or vice versa. |
|
|
Check Required |
Displayed when there is some doubt about the comparison results and should be manually checked, for example: a tee has been matched according to the pattern of the model but it is not certain. |
|
|
Information |
Indicates a condition that is not normally a problem for comparison but the user may need to be aware of, for example: schematic tube between elements but no 3D tube equivalent because the model is fitting to fitting. |
|
|
Warning |
Displayed when Integrator detects something that is relevant to the comparison but not directly a difference, for example: a component which is not positioned corrected. |
|
|
Not Compared |
Indicates part of the model that falls within the scope of comparison but is deliberately excluded, for example a branch forming a support trunnion. |