Component End Conditions Defined By P-Points
- Last UpdatedJul 28, 2025
- 1 minute read
The symbols used to represent piping components on isometrics, as defined by the SKEYs described in the section Symbol Keys, can be drawn with different end conditions (that means, with different connection types). The connection types which may be represented are:

Component end conditions
By default, each SKEY has one standard end condition which applies to all its connection points. A different end condition can be set for individual connection points for the following types of components:
|
BEND |
CROS |
ELBO |
FILT |
FLAN |
|
INST |
OLET |
PCOM |
REDU |
SHU |
|
TEE |
TRAP |
VALV |
VFWA |
VTWA |
P-point elements of type PTAXI, PTCAR and PTMIX have a PSKEY (P-point Symbol Key) attribute which is, by default, set to NULL, so that Isodraft uses the standard end connections defined for that SKEY.