Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

THRE circular requirements

  • Last UpdatedApr 14, 2025
  • 2 minute read

This topic describes the specification requirements for circular three-way (THRE) components.

Parameter description requirements

  • Parameter #1 = Width of arrive

  • Parameter #2 = Width of branch

Data set requirements

For information about data set requirements that apply for all circular components, refer to Circular component requirements.

The following requirements are in addition to the data references that are created for parameters.

KEY

Type

Description

Default ( /Expression **)

SHAP

Null

Duct shape

‘CIRC’

AARR

Distance

Width of arrive

PARA[1 ]

BARR

Distance

Height of arrive

0

ALEA

Distance

Width of leave

PARA[1 ]

BLEA

Distance

Height of leave

0

ABRA

Distance

Width of branch

PARA[2 ]

BBRA

Distance

Height of branch

0

** Where the Default value is set to a parameter, the Expression value must be set to the same parameter. This is applicable for all component types.

P-point requirements

For information about P-point requirements that apply for all circular components, refer to Circular component requirements.

The P-point P3 defines the position, direction, and size of the three-way off-leg, and the required attribute settings.

The following table shows the additional required P-points:

Type

Connection Type (PCON)

Bore (PBOR)

Axis Direction (PAXI)

PZ Axis (PZAXI)

Point Width (PWID)

PDShape attribute

AllAngle attribute

1

PTAX

CIRC

(RPRO AARR + RPRO BARR)

-Z

Y

(RPRO AARR + RPRO BARR)

CIRC

1

2

PTAX

CIRC

(RPRO ALEA + RPRO BLEA)

Z

Y

(RPRO ALEA + RPRO BLEA)

CIRC

1

3

PTAX

CIRC

(RPRO ABRA + RPRO BBRA)

X

Y

(RPRO ABRA + RPRO BBRA)

CIRC

1

61

PTMI

0

0

Y

unset

unset

0

unset

62

PTMI

0

0

Y

unset

unset

0

unset

63

PTMI

0

0

Y

unset

unset

0

unset

64

PTMI

0

0

Y

unset

unset

0

unset

The P-points are arranged as shown in the following graphic:

Specification requirements

The following specification headings are required:

  • Type (TYPE)

  • Duct Shape (PSHA)

  • Duct Width 1 (PWID1)

  • Duct Height 1 (PHEI1) = 0

  • Duct Width 3 (PWID3)

  • Duct Height 3 (PHEI3) = 0

Duct Width 3 and Duct Height 3 are used to describe the offline connection.

In This Topic
TitleResults for “How to create a CRG?”Also Available in