COORDINATES or COORDS
- Last UpdatedJul 14, 2025
- 2 minute read
|
Function: |
Specifies the drawing locations at which spatial coordinates are to be shown. |
|
Description: |
Spatial coordinates are shown on the drawing, by default, at all pipe termination or connection points. The user can stop coordinates being plotted at specified types of location on the isometric. |
|
Examples: |
COORDS OFF No end coordinates will be shown. COORDS ON All end coordinates will be shown. COORDS ON AT PIPE NOZZ VENT End coordinates will be shown only at pipe continuations, Nozzle connections and Vents. COORDS ON AT MISCELLANEOUS End coordinates will only be shown at end locations which are not any of the following: Pipe, Nozzle, Open, Clos, Vent or Dran. For example, coordinates will be shown at an unconnected flange. COORDS OFF AT VENT DRAN CLOS Suppresses coordinates at the specified types of component. Coordinates will be plotted at all other types of pipe termination or connection. COORDS ON AT SHEET Specify that spatial coordinates are to be shown at sheet break on the same isometric. |
|
Related Commands: |
ELEVATIONS |
|
Command Syntax: |
>--+-- COORdinates --. |
|
Querying: |
Q COORdinates Q COORDS Q OPTions |