Customizing the Main Body of the Report
- Last UpdatedFeb 19, 2025
- 3 minute read
Keywords
REPORT MAIN SECTION POSITION REF NUMBER PRIMARY SIGNIFICANT FIRST SECOND BOTH REMOVE
Description
The standard format shows each clash on a separate line, with full details of the clashing items and the nature of the clash. The reported clashes are grouped into sections, each of which lists all clashes within a single significant element, the name of which is usually shown only at the beginning of the section to avoid excessive repetition of data (the name of the second clashing element is always shown in full to avoid any ambiguity).
The following details may also be included in the report:
-
The clash position, in either Site or World co-ordinates (to control how this position is calculated, refer to Controlling the Reported Clash Position).
-
The AVEVA E3D Design reference numbers of the clashing elements, as well as their names.
-
Sequential clash numbers, used to identify individual clashes in other commands (such as when approving clashes).
-
By default, all types of clash, touch and clearance are reported. To restrict the report to one or more specified clash types (for example, hard/hard only, touches only)
.
Examples
REPORT MAIN OFF
Suppresses main body of report
REPORT MAIN
REPORT MAIN ON
Reinstates main body if previously suppressed (ON is the default)
REPORT POSITION SITE
Shows clash positions in Site coordinates
REPORT POSITION WORLD
Shows clash positions in World coordinates
REPORT POSITION OFF
Suppresses clash positions (the default)
REPORT REF
REPORT REF ON
Outputs reference numbers of clashing items
REPORT REF OFF
Suppresses reference numbers (the default)
REPORT NUMBER
REPORT NUMBER ON
Outputs sequential clash numbers.
REPORT NUMBER OFF
Suppresses clash numbering (the default)
REPORT FIRST
List clash only under first item in DB hierarchy (the default)
REPORT SECOND
List clash only under second item in DB hierarchy
REPORT BOTH
List clash twice, once under each item in DB hierarchy
REPORT PRIMARY
REPORT PRIMARY ON
Reports only first or highest priority clash found between two significant elements (i.e. suppresses multiple clashes) but also shows actual number of clashes which would have been reported if this option were not in force.
REPORT PRIMARY 500
Suppresses multiple clash reports if clash positions are less than 500 mm apart (if current units are mm)
REPORT PRIMARY OFF
Reports all clash occurrences, including those between different primitives of the same pairs of significant elements (the default)
REPORT SIGNIFICANT
REPORT SIGNIFICANT ON
Lists all significant elements which have been checked, not just those for which clashes have been detected.
REPORT SIGNIFICANT OFF
Reports only those significant elements which involve clashes (the default)
REMOVE SECTIONS SUBS STRUC
Suppresses the labelling of those sections of the report which represent Substructures and Structures. Clashing items in these sections will be identified by their full name on each line (in the same way that the second clashing element is always shown)
SECTIONS SUBS STRU
Reinstates labelling of specified sections
Command Syntax
.---------------<-----------------.
/ |
>--- REPort ---*--- POSition ---+--- SIte ----. |
| | | |
| |--- WOrld ---| |
| | | |
| ‘--- OFF -----+----|
| |
|--- REF -----------. |
| | |
|--- NUMber --------| |
| | |
|--- MAIN ----------| |
| | |
|--- PRImary -------| |
| | |
|--- SIGnificant ---+--- <onoff> ---|
| | |
| ‘---------------|
| |
|--- PRImary --- <uval> ------------|
| |
|--- FIRst -------------------------|
| |
|--- SECond ------------------------|
| |
|--- BOTh --------------------------’
|
| .-----<-------.
| / |
|---*--- <cltyp> ---|
| | |
| ‘--- NP --------+---. .-------<--------.
| | / |
|--- ALL ---------------+---*--- CLAshes ------|
| | |
| |--- TOUches ------|
‘---> | |
|--- CLEarances ---|
| |
‘------------------+--->
>---+--- REMove ---. .----<------.
| | / |
‘--------------+--- SECtions ---*--- <sig> ---+--->
where <sig> (significant element) is any of the following:
|
SITes |
ZONes |
PIPes |
BRAnches |
EQUipments |
|
STRuctures |
SUBStructures |
HANGers |
RESTRaints |
PTRacks |
|
FRMWorks |
SBFRMworks |
Querying
Q CLASH REPort MAIN
Q CLASH REPort POSition
Q CLASH REPort REF
Q CLASH REPort NUMber
Q CLASH REPort PRImary
Q CLASH REPort SIGnificant
Q CLASH REPort DUPlication
Shows under which sections clashes will be reported (First, Second or Both)
Q CLASH REPort LEVel
Lists clash types to be reported on
Q CLASH REPort
List all report settings (header + main + summary)