Tables
- Last UpdatedDec 11, 2023
- 1 minute read
In database terms the Table is a NOTE of the Backing Sheet (BACK); there are two notes required, one for the Table headings and one for the Table cells. Both notes are positioned at the same point.
Example:
|
BACK named /DRA/MAS/BACKS/HVACSketch/A4 SETST |
|
|
NOTE named */ExampleTable function 'ENDPOINT SpPurpose 'TABLE' |
|
|
NOTE named */ExampleCells function 'ENDPOINT SpPurpose 'CELLS' |
|

The above is an example of a table defined on a backing sheet. Although this table is visible in the view, it will in practice have its visibility flag (LVIS) set to false. The reason being that this table is used by copying onto the HVAC Sketch Drawing then the cells of the table are populated with data from the actual HVAC Spool. The figure below shows the table in situ on the final HVAC Sketch Drawing.