Idealized Model Hierarchy
- Last UpdatedNov 09, 2023
- 1 minute read
The AVEVA E3D Design structural model does not have any idealized data written directly to it. All the data is either stored on the idealized model or can be obtained via the link from the idealized model components.
The following database elements are common to the idealized model:
Idealized World (IDLWLD)
The IDLWLD element is the highest level of the idealized model database hierarchy within which all other elements exist.
Idealized Structure (ISTRU)
The ISTRU element is linked to the AVEVA E3D Design STRU element.
Idealized Structure Revision (ISTRUR)
Each export or import creates a new ISTRUR based on the latest information from either the AVEVA E3D Design structural model or the Staad Pro STD file. The revision numbers are automatically incremented.
Idealized Section (ISECT)
The ISECT element is linked to the AVEVA E3D Design GENSEC element.
Idealized Node (INODE)
The INODE element is usually coincident with a joint connection linked to a JLDATU element or ENDATU element.
Idealized Panel (IPANE)
The IPANE element is linked to the AVEVA E3D Design PANE element.