Arguments

1

HELE STYP

2

Any other selectors (quoted if using TANS)

3

HELE GTYP. Unique WORD attribute used to identify HELE for later operations

4

GTYP of element which will be at the arrive end of the new HELE

5

GTYP of element which will be at the leave end of the new HELE

N.B. If argument 4 identifies an element which occurs later in the hanger's members list than argument 5, this will cause the new element to be created in ‘backwards’ mode. This can be very useful in some circumstances

6

Arrive p-point/Leave p-point (e.g. 2/1)

7

Connection/Fitting instructions:

FIT: Fit the HELE into the available space (by setting HEIGHT attribute)

CONN: Connect the HELE to the previous element (or HH/HT)

DIST: Set the HELE at a specified distance from the previous element

PROP: Set the HELE at a specified proportional distance between the previous and the next elements

DIST and PROP both have the format <keyword> <value> <p-point> (the p-point designation is optional and defaults to P0)

8

Angle flag. True if the component has a DDANG which needs to be deduced.

9

Specification from which to select component:

INSPEC: Select from current HSPEC

PSPEC: Select from attached pipe PSPEC

<gid>: Select from explicit specification

Globals used

!!CDSNHB.RINS1

Rod insertion length at P1

!!CDSNHB.RINS2

Rod insertion length at P2

Globals set

!!CDSNHB.RTOVAL1

Derived RTO value at P1 end

!!CDSNHB.RTOVAL2

Derived RTO value at P2 end