Reference grids can be used on ADP drawings. By default, gridline functionality is not available. Gridline functionality can be made available.

The gridline application defaults files are;

%PDMSUI%\dflts\dra-genadp-equilocn

%PDMSUI%\dflts\dra-genadp-piping

%PDMSUI%\dflts\dra-genadp-plotplan

%PDMSUI%\dflts\dra-genadp-supports

The following setting indicates that gridline functionality is not available:

var !!CDDIMLEV3FLG |FALSE|

To make the gridline functionality available, modify the setting to:

var !!CDDIMLEV3FLG |TRUE|

To remove the generation of reference grid annotations, modify the relevant view visual style property AGMODE to OFF.