Running an Obstruction Box Check
- Last UpdatedFeb 19, 2025
- 1 minute read
Keywords
BOXCHECK
Description
The BOXCHECK command initiates only a simplified (Stage 1) check for clashes between specified items (the check list) and the current obstruction list.
Examples |
|
|---|---|
|
BOXCHECK ALL |
Checks all items in the design model (within any restrictions defined as in Sections 3.3 to 3.9) against the obstruction list. |
|
BOXCHECK /ZONE1.PIPES BOXCHECK /PUMP1 /PUMP2 /VESS2 BOXCHECK /GROUP.MOD2 BOXCHECK LEAVE TUBE FROM /FLAN2 IARRIVE TUBE TO /VALV5 |
Checks only specified items against the obstruction list. |
Command Syntax
.-----<------.
/ |
>--- BOXCHeck ---*--- <clid> ---+---.
| |
‘--- ALL ----------+--->
where <clid> (clashing item identifier) has the syntax shown in Running a Full Component Check.