Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

Running an Obstruction Box Check

  • Last UpdatedFeb 19, 2025
  • 1 minute read

Keywords

BOXCHECK

Description

The BOXCHECK command initiates only a simplified (Stage 1) check for clashes between specified items (the check list) and the current obstruction list.

Examples

BOXCHECK ALL

Checks all items in the design model (within any restrictions defined as in Sections 3.3 to 3.9) against the obstruction list.

BOXCHECK /ZONE1.PIPES

BOXCHECK /PUMP1 /PUMP2 /VESS2

BOXCHECK /GROUP.MOD2

BOXCHECK LEAVE TUBE FROM /FLAN2 IARRIVE TUBE TO /VALV5

Checks only specified items against the obstruction list.

Command Syntax

                       .-----<------.
                      /             |
    >--- BOXCHeck ---*--- <clid> ---+---.
                     |                  |
                     ‘--- ALL ----------+--->

where <clid> (clashing item identifier) has the syntax shown in Running a Full Component Check.

In This Topic
TitleResults for “How to create a CRG?”Also Available in