Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

Parameters

  • Last UpdatedMay 09, 2023
  • 2 minute read

The Parameters tab displays a table of the design parameters for the selected ancillary for each bore size. The listed parameters can be modified.

Click and drag the vertical column separator lines to modify the width of table columns.

When a table row is selected, the selected bore size is populated in the Size, Alternate Expression and User Design Parameters tabs. For example, when switching to the Size tab, the selected bore is displayed and can be modified.

Right-click the currently selected cell to display a drop-down menu.

Copy

Copies the currently selected cell value. The value is stored on the clipboard for a later paste operation.

Paste

Pastes the cell value that is stored on the clipboard into the currently selected cells.

Fill Down

Copies the cell value from the top cell in a selection of cells and pastes it into all cells in the selection.

Fill Up

Copies the cell value from the bottom cell in a selection of cells and pastes it into all cells in the selection.

Nom Bore

Defines the size (bore) of the pipe. The pipe defaults apply to the size of the pipe selected.

Active

The setting determines the pipe bore sizes that the support ancillary can be attached to.

If the cell value is Active, the support ancillary can be attached to the pipe bore size.

If the cell value is Inactive, the support ancillary cannot be attached to the pipe bore size.

Click on a cell to modify the Active setting.

Shop

The setting determines whether the material for an ancillary appears on the piping isometric material list under the FABRICATION MATERIALS (SHOP TRUE) or ERECTION MATERIALS (SHOP FALSE) heading of the MTO.

If the cell value is Fabrication materials, the material for the ancillary appears on the piping isometric material list under the FABRICATION MATERIALS (SHOP TRUE).

If the cell value is Erection materials, the material for the ancillary appears on the piping isometric material list under the ERECTION MATERIALS (SHOP FALSE).

Material Code

Provides the same information as Pipe Specification Material Code, but overrides the standard setting for the selected bore.

Ancillary Material

Provides the same information as Propcon - MDS Ancillary Material, but overrides the standard setting for the selected bore.