Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

Create Pull Pit Branch

  • Last UpdatedMay 16, 2025
  • 5 minute read

Use the functionality to create a new Pull Pit Branch element.

To create an new Pull Pit Branch

  1. Select the Cabling System discipline.

  2. In the Model Explorer, select the CWAY-PULL-PITTS-Area, in which a new Pull Pit Branch must be created.

  3. On the Cabling System tab, in the Create area, select Pull Pit Branch function.

    The Create Pull Pit Branch tab is displayed on one side of the application window

Create CWAY in this Zone

Displays the currently selected zone identified in the Model Explorer.

CWAY Name

Defines the name of the new Pull Pit Branch.

Cableway Branches

Defines the cable way branches attributes:

Diameter

Specifies the diameter (default is displayed).

Bend Radius

Specifies the bend radius (default is displayed).

Number

Specifies the number of branches (vertical and horizontal) (default is displayed).

Spacing

Specifies the spacing (default is displayed).

Overall Duct

Specifies the overall duct size (default is displayed).

No Tail Pull Pit/Junction Box

Use if only a head connection is required.

If you select the No Tail Pull Pit/Junction Box option, the Straight line distance option becomes available.

Straight line distance

Defines how long the head will extend from the head connection.

Manual Route

Manually modifies the route of the cable with defined route points.

If you select the Manual Route option the Route point tab becomes available and the some other options are displayed.

Note: When pull pit branches are routed between pull pits/junction boxes the route is automatically defined.

Cableway Head tab

Displays all cableway heads within the currently selected zone in the cableway head list (default).

Cableway Tail tab

Displays all cableway tails within the currently selected zone in the cableway tail list.

Pick Pull Pit or Junction Box in 3D View

Picks the required pull pit or junction box in the 3D view.

Refresh List

Refreshes the cableway head/tail list.

Head Direction

Automatically displays the head direction.

Head/Tail Position WRT Zone

If you selected the head/ teal position, the coordinates are automatically displayed, amend if required.

Offset Positions the head/tail position using an offset.

Lock Locks the co ordinates.

Pick New Head Position

Picks a new head/tail head position in the 3D view.

90 degree bends

Specifies that 90 degree bends are used where possible.

Route Points tab

By default, the Route Points tab is blank.

Route Point Position WRT Zone

Format

Explicitly positions the route point at E0, N0, U0 by default.

ENU

XYZ

Grid

Offset

Positions the route point using an offset, default is 0mm.

Copy Head Position

Copies the head position of the Pull Pit Branch

Copy Tail Position

Copies the tail position of the Pull Pit Branch

WRT current element

Identifies the pull pit branch WRT to the currently selected element.

WRT CE Owner

Identifies the pull pit branch WRT to the currently selected element’s owner in the model hierarchy.

WRT world

Identifies the pull pit branch WRT to the WORLD element in the Model hierarchy.

WRT picked element

Identifies an element in the current 3D graphical view.

Pick Route Point Position

Identifies the route point position in the 3D graphical view.

Offset mode

Sets Offset mode.

Returns form Offset mode.

Lock

Locks the coordinate entry.

Unlocks the coordinate entry.

Add before

Adds the route point before the currently selected element in the Route Point grid.

Add After

Adds the route point after the currently selected element in the Route Point grid.

Replace

Replaces the currently selected element in the Route Point grid with a newly identified route point.

Remove

Removes the route point from the 3D view.

Mark all route points

Defines the use of rout points.

If you select the Mark all route points check box, the application identifies route points in the 3D view and labels it.

If you do not select the Mark all route points check box, the application does not consider the identification of the route points.