During project creation, where a DBA login is required, it’s possible to provide a ‘DBA’ login with insufficient rights, that is with rights to create some parts of the schema and not others.

This can lead to the user being unable to edit or delete the connection using ClashManager options. If this occurs, the incomplete database username should be removed using DBA admin tools and the failed connection removed from the ClashManager configuration file (in the 3D project DFLTS folder).

If there is at least one other correctly configured database connection, it may be used together with the Administrator Options in ClashManager to remove the failed connection from the ClashManager configuration file.

If there are no other correctly configured database connections, the ClashManager configuration file may simply be deleted.