Description

The spread direction is the direction in which the pipes will be spread laterally when they are ordered along the rack. The default position from which the pipes are spread is the center of the PVOL. This may be changed to the side of the PVOL by adding the parameter FROMSIDE to the command.

Examples

SDIR E

Sets the spread direction to be East about the centre of the PVOL

SD N FR

Sets the spread direction to be North, starting from the south side of the PVOL

SD N AB

As above, but pipes to be spread about centre of rack

Note:
If no spread direction is specified, the default is taken as the direction of the second largest side of the PVOL

Command Syntax

>-- SDir <bdir> --+-- FRomside -----.
                  |                 |