Dependency on Cable Way Path Data

  • Last UpdatedNov 13, 2023
  • 1 minute read

The Supports application is dependent on the correct definition of the cable way path data and the consistency of the dressed material. The inside radius is used to determine the bend start and end points for CTBEND and CTTEE elements, and hence if the support lies on a tangent straight or on the curve.

In the example, the inside radius has been defined as too short in the RPATH data (INSRAD of POSREF of the CTTEE), and so the start of the angle has moved away from the end of the tangent length where it would be expected to lie.