Running a Full Component Check
- Last UpdatedFeb 19, 2025
- 1 minute read
Keywords
CHECK
Description
The CHECK command initiates a full two-stage check for clashes between specified items (the check list) and the current obstruction list.
Examples |
|
|---|---|
|
CHECK ALL |
Checks all items in the design model (within any restrictions defined as in Sections 3.3 to 3.9) against the obstruction list. |
|
CHECK /ZONE1.PIPES CHECK /PUMP1 /PUMP2 /VESS2 CHECK /GROUP.MOD2 CHECK LEAVE TUBE FROM /FLAN2 IARRIVE TUBE TO /VALV5 |
Checks only specified items against the obstruction list. |
Command Syntax
.-----<------.
/ |
>--- CHEck ---*--- <clid> ---+---.
| |
‘--- ALL ---------+--->
where <clid> (clashing item identifier) is
>---+--- ILEAve ---.
| |
|--- IARRIVE --|
| |
|--- HEAD -----|
| |
|--- TAIL -----+--- TUBe ---.
| | |
| |--- ROD ----|
| | |
| ‘------------+--- OF -----.
| | |
| |--- FROM ---|
| | |
| |--- TO -----|
| | |
| ‘------------+
| |
‘----------------------------------------+--- <gid> -->