Convert Custom Setting
- Last UpdatedJan 13, 2023
- 2 minute read
Use the functionality available from the HVAC Custom Setting Converter window to covert a detailing specification from the previous version of HVAC (in the previous version a text file) and transfer it to Paragon. Where each custom setting is stored under a Catalog (CATA) element as a SECT.

From |
|
|
File |
Navigate to location of the required detailing specification. |
|
Sheet Material |
The material (custom setting) associated with the detailing specification is displayed. |
|
Filename |
The file name of the detailing specification is displayed. |
To |
|
|
Current Cata |
Use to specify where the detailing specification will be place once converted. |
|
Rename |
If required rename the detailing specification. |
|
Description |
Enter a description for the converted detailing specification. |
|
Sheet Material |
If required, select a new custom setting for the material, available material settings are: A material from a Material World (MATW) element must be selected for the newly converted custom setting, any materials (for example: SOLI) with purpose HVAC can be selected here. |
On successful conversion of the previous detailing specification a message is displayed in the Messages pane of the HVAC Custom Setting Converter window.