Reference Pointers and Settings
- Last UpdatedJan 13, 2023
- 1 minute read
The pointers and settings must be place in the correct order. The following headings meet the requirement:
DESPAR - Design Parameters:
Specifies design parameters relating to the joint selection. The design parameters are a text string which is used to populate the DESP attribute on the FIXING.
CATREF - Catalog Reference:
Specifies the Catalog component referenced by the specification component.
TMPREF - Template Reference:
Specifies the design template component referenced by the specification component.