The piping specific hierarchy contains information such as branch, reducer, nominal bore, bolting or connection tables which are part of the catalog database.

These tables are a collection of similar elements in the database which the administrator can group together elements to help with creation of specifications such as bore ranges, branch and reducer types, wall thickness and pipe data. Refer to Wall Thickness Table, Pipe Data Table and Create Nominal Bore World for further information. On all windows, click Apply or OK to save the changes or click Cancel to discard any inputs and close the window.

The Connection Compatibility Table hierarchy holds a list of all the compatible connection types for Piping Components in a set project. Refer to Coco Table for further information.

The Bolt Table hierarchy contains information describing the nature of the bolted connections of Piping Components in a project. Refer to Bolt Diameter and Length Tables for further information.

Table World

The Table World (TABWL) is a top level administrative element, which can own one or several administrative table elements:

  • Nominal bore size table

  • Branch and reducer tables

  • Pipe data tables

  • Wall thickness tables.

Many multi-purpose windows provide similar functionality through the create and modify options. Refer to Multi-Purpose Windows for further information.

Nominal Bore Table

A Nominal Bore Table (NOMTAB) element is the administrative element for a nominal bore table and must be created below a Table World (TABWLD) element.

Note:
The Nominal Bore Table does not provide wall thickness data in the model, refer to Wall Thickness Table for further information.

Note: For nominal bores that are not included in the standard nominal values, refer to Create Nominal Bore World for further information.

Many multi-purpose windows provide similar functionality through the create and modify options, the functionality is common throughout all disciplines. Refer to Multi-Purpose Windows for further information.

Once the administrative elements have been created, the Size Range window is displayed. By default, the Name fields are automatically populated, the Description is Unset and the Purpose is set to PIPE, as the currently active discipline is PIPING.

Click to highlight the desired bore sizes in the Available Nominal Bores (mm) list. Multiple bores can be selected at once by left clicking and dragging the mouse pointer. To remove particular highlighted entries hold down the CTRL key and left click on a bore size.

ADD >

Adds highlighted bore size to the Nominal Bores part of the Size Range window.

ADD ALL >>

Adds all highlighted bore size to the Nominal Bores part of the Size Range window.

Remove <

Removes the highlighted bore size to the Nominal Bores part of the Size Range window.

Remove All <<

Removes all the highlighted bore size to the Nominal Bores part of the Size Range window.

Create Branch Tables

Branch tables are used as a way of selecting the type of fitting used for example BW could indicate a Butt Weld Tee, SW a Socket Weld Tee, WOL a Butt Weld Outlet Boss and SOL a Socket Weld Outlet Boss. A Branch Table (BRTAB) element must be created below a Table World (TABWLD) element.

Many multi-purpose windows provide similar functionality through the create and modify options, the functionality is common throughout all disciplines. Refer to Multi-Purpose Windows for further information. Once the BRTAB is created, the Branch Table window is displayed.

By default, the name fields are automatically populated, the description is Unset and the Purpose is set to BRAN, as the currently active discipline is PIPING.

Click to highlight the desired bores in the Available Nominal Bores (mm) list by left clicking on the desired bore size. Multiple bores can be selected at once by left clicking and dragging the mouse pointer down the list.

ADD >

Adds highlighted bore size to the Branch Size part of the Branch Table.

ADD ALL >>

Adds all of the highlighted bore size to the Branch Size part of the Branch Table.

Remove <

Removes the highlighted bore size to the Branch Size part of the Branch Table.

Remove All <<

Remove all of the highlighted bore size to the Branch Size part of the Branch Table.

Short codes are under user control and are stored in the defaults file: PMLUI\dflts\cat-pipetablecodes.

Once the desired bores have been added to the Branch Table, short codes can be added. From the Cell Click Action part of the Branch Table, click Add.

BW

TR

PAD

SOL

SW

ST

WOL

WOF

TOL

STUB

TOL

In the Main Bores part of the Branch Table window, click on the required empty cells to add the short code.

To add the short code to multiple cells, select multiple cells by holding down CTRL and left clicking and dragging the mouse pointer.

To remove short codes, from the Cell Click Action part of the Branch Table window, select Clear and left click on the cell within the Branch Table.

To return the mouse pointer to normal operation, from the Cell Click Action part of the Branch Table window, select None.

Reducer Sizes

The Reducer Sizes check box is only active when used in conjunction with the Specification creation windows. When a Spec is associated with a Specification Table this check box allows the quick switching between windows allowing faster edits to be made.

Create Reducer Tables

The Reducer Table creation window behaves in exactly the same manner as the Branch Table window. To avoid repetition this section only lists the differences between the two. A Reducer Table must be created below a Table World (TABWLD) element.

Many multi-purpose windows provide similar functionality through the create and modify options, the functionality is common throughout all disciplines. Refer to Multi-Purpose Windows for further information. Once the Reducer Table (BRTAB) element, the Reducer Table window is displayed.

By default, the name fields are automatically populated, the description is Unset and the Purpose is set to REDU, as Reducer has been selected from the Create Specification Table group.

The only difference in behaviour to the Branch Table window is the list of Short Codes available for selection, by default, these are:

ECC

CONC

SWGE

SWGC

Short codes are under user control and are stored in the defaults file: PMLUI\dflts\cat-pipetablecodes. Populate the table as described in the previous section.

COCO Table

The Connection Compatibility Table (CCTA) holds a list of all the compatible connection types for Piping Components in a set project. A CCTA is an administrative element which exists at the same level as CATA in the hierarchy. A CCTA has Connection Compatibility (COCO) elements as its members, each of which has a pair of coded connection types stored as its CTYPE attribute. These connection types are those referred to in the PCON attribute of a Piping Component’s P-points.

Many multi-purpose windows provide similar functionality through the create and modify options, the functionality is common throughout all disciplines. Refer to Multi-Purpose Windows for further information. Once the Coco table element is created, the Connection Compatibility Table window is displayed.

Note:
If the connection compatibility table is from a read-only primary project, an error message is displayed. The table is displayed and the data in the Connections grid is readable but the table will be in read-only mode.

From the Connection Types part of the Connection Compatibility Table window, select the required connection types from the list of available connections. Multiply selections can be made by holding down the CTRL key and using the left click on the mouse.

From the Connection Types part of the Connection Compatibility Table window, click to highlighted a connection type to the Connections grid then by click Add >.

Note:
When a connection type is added from the Connections Types list to the Connections grid, it is removed from the Connections Types list and vice versa.

Add >

Adds the highlighted connection type to the Connections part of the Connection Compatibility Table.

Add All >>

Adds all of the highlighted connection type to the Connections part of the Connection Compatibility Table.

Remove <

Removes the highlighted connection type to the Connections part of the Connection Compatibility Table.

Remove All <<

Remove all of the highlighted connection type to the Connections part of the Connection Compatibility Table.