Default value

Session/default catalog modifiable

Description

1/10

Session

Maximum allowable pipe slope for horizontal supports.

The slope value above which the Supports application creates a framework support perpendicular to the pipe.

Below this slope value, the Supports application allows the pipe to sit at an angle relative to the vertical framework.