Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

Controlling the Detailed Checking Procedure

  • Last UpdatedJan 13, 2023
  • 1 minute read

You can modify the effect of the CHECK command by using additional syntax so that you can check different types of Catalog without generating unnecessary errors.

The command options are as follows:

TOLerance CATAlogue CMPRef ON/OFF

switches Component Reference checking on or off for all component types in a Specific Component (SPCO).

TOLerance CATAlogue CMPRef word ON/OFF

switches Component Reference checking on or off for the specified component type in a SPCO.

TOLerance CATAlogue GMREf ON/OFF

switches Geomset Reference checking on or off for all component types.

TOLerance CATAlogue GMREf  word  ON/OFF

switches Geomset Reference checking on or off for the specified component type.

TOLerance CATAlogue BORE ON/OFF

switches bore checking on or off for Pointsets.

TOLerance CATAlogue BORE  value  value

sets range of permissible bores to be checked for Pointsets.

TOLerance CATAlogue ISOMetric ON/OFF

checks for SKEY and similar Isodraft‑related settings.

TOLerance CATAlogue DEFault

resets all checking options to their default settings.

These defaults are:

  • Do not check any CMPREFs.

  • Ignore GMREF settings for Attachment Points (ATTA), FLAN, TUBE and BOLT.

  • Check nominal bores in the range 6 mm to 2150 mm.

  • Check all Isodraft-related settings.

To query any of the current data consistency checking settings, use the corresponding command format

Q TOLerance CATAlogue ...