Modify Restraint Attributes
- Last UpdatedAug 25, 2022
- 2 minute read
Use the PSI Support Node window to modify support node data.
CAESAR II versions prior to CAESAR II 2018 allow the transfer of four different support restraint types.
If the PSI Support Node window is opened for compatibility with CAESAR II versions prior to CAESAR II 2018, a warning is displayed, indicating that User Defined Attribute (UDA) definitions must be updated to enable compatibility with CAESAR II 2018 and beyond.

Click OK to open the PSI Support Node window to modify support node data for a maximum of four different support restraint types.
To update the Pipe Stress Interface UDAs for compatibility with CAESAR II 2018 and beyond, refer to the system administrator.

Click Current Element to identify the required node as the CE.
CAESAR II 2018 and beyond allow the transfer of six different support restraint types.

Click Current Element to identify the required node as the CE.
Note:
If six restraint types are entered but a CAESAR II 2018 template file is not selected
for output, only the first four restraint types are transferred. To update the Pipe
Stress Interface template file for compatibility with CAESAR II 2018 and beyond, refer
to the system administrator.