Specifying Minimum Lengths Irrespective of Bore

  • Last UpdatedFeb 19, 2025
  • 1 minute read

Keywords

TOLERANCE TUBE

Description

The TUBE command, used alone, specifies the minimum acceptable tube length which is applicable to all tube diameters which have not been more specifically set.

Examples

TOL TUBE 100
(Default)

Minimum acceptable length is 100 mm

TOL TUBE DEFAULT

Minimum acceptable length is 100 mm

TOL TUBE 6 INCH

Minimum acceptable length is 6 inches

Command Syntax

>-- TOLerance TUbe --+-- <uval> ---.
                     |             |
                     ‘-- DEfault --+-->

Querying

>-- Query TUbe -->

>-- Query TOLerance OPTions -->

(also outputs ATTACHECK and misalignment settings; refer to Checking Parts of the Design and Piping/Hangers, respectively)