Known Error Messages
- Last UpdatedJan 23, 2023
- 5 minute read
|
Error |
Description |
|---|---|
|
125, 26 - No Space 'Layout failed - Insufficient space in branch /CWAY-POWER02-BUILDING-B01/B1 to lay /CBLP-B01-AHU-001-01' |
This error is displayed when trying to lay a cable in insufficient space within a 'routing volume'. In this example: there is not enough space on the branch /CWAY-POWER02-BUILDING-B01/B1 to lay cable /CBLP-B01-AHU-001-01. |
|
125, 27 - Invalid Radius Layout failed - Radius of /CBLP-B01-AHU-001-01 in branch /CWAY-POWER02-BUILDING-B01/B1 would be less than minimum bend radius' |
This error is displayed when trying to lay a cable, in the only place available and as a result causes the cable’s bend radius to be smaller than the minimum. In this example: the radius of cable /CBLP-B01-AHU-001-01 when being laid on the branch /CWAY-POWER02-BUILDING-B01/B1 causes the bend radius to be less than the cables minimum bend radius. |
|
125, 28 - Invalid Element 'Layout failed - Element /EQUI-B01-AHU-02-001 is not a routing object' |
This error is displayed when trying to perform layout on an element that is not of the correct type. In this example: the element /EQUI-B01-AHU-02-001 which is an Equipment, is not of the correct type to perform layout on. |
|
125, 29 - Maxlay Reached - 125, 29 'Layout failed - Exceeded maximum layers(3) in branch /CWAY-POWER02-BUILDING-B01/B1' |
This error is displayed once the limit of layers on a tray is reached. (When multiple cables are stacked to fit them onto the tray (branches can be restricted to a certain number of layers). In this example: to lay a cable we will have to exceed the maximum number of layers (which is 3), on the branch /CWAY-POWER02-BUILDING-B01/B1. |
|
125, 30 - Can Not Be Touching 'Layout failed - /CBLP-B01-AHU-001-01 and /CBLP-B01-AHU-001-02 would be touching’ |
Laying cables have rules applied to them, one of these rules is that certain cables cannot touch. This error is displayed when a cable touches another cable which has been be identified as prohibited. The rule is applied when laying a cable or verifying existing laid cables. In this example: cables /CBLP-B01-AHU-001-01 and /CBLP-B01-AHU-001-02 would be touching, producing an invalid layout. |
|
125, 31 - Can Not Stack Bigger Cable 'Layout failed - Can not put bigger object /CBLP-B01-AHU-001-01 on top of smaller object /CBLP-B01-AHU-001-02' |
This error is displayed when larger cables are stacked on top of smaller cables. The rule is applied when laying a cable or verifying existing laid cables. In this example: the larger cable /CBLP-B01-AHU-001-01 cannot be placed on top of the smaller cable /CBLP-B01-AHU-001-02. |
|
125, 32 - Layer Not Aligned 'Layout failed - /CBLP-B01-AHU-001-01 and /CBLP-B01-AHU-001-02 are not layered correctly' |
This error is displayed when stack cable’s centres are not aligned. The rule is applied after laying a cable, or verifying existing laid cables. In this example: cables /CBLP-B01-AHU-001-01 and /CBLP-B01-AHU-001-02 are not layered correctly. |
|
125, 33 - Not Tried 'Layout failed - Layout process could not begin’ |
This error is displayed when the layout process is unable to begin. |
|
125, 34 - First Layer Not At Bottom 'Layout failed - /CBLP-B01-AHU-001-01 is not at bottom in branch /CWAY-POWER02-BUILDING-B01/B1' |
This error is displayed when laying cables, the first layer is not on the bottom of the routing volume. In this example: the layer which cable /CBLP-B01-AHU-001-01 has been laid on is not at the bottom of the branch /CWAY-POWER02-BUILDING-B01/B1. |
|
125. 35 - Collision 'Layout failed - /CBLP-B01-AHU-001-01 collides with /CBLP-B01-AHU-001-02' |
This error is displayed when cables collide with one another. The rule is applied after laying a cable or verifying existing laid cables. In this example: the cable /CBLP-B01-AHU-001-01 collides with cable /CBLP-B01-AHU-001-02. |
|
Segment Not Found - 125, 36 'Layout failed - Branch /CWAY-POWER02-BUILDING-B01/B1 does not have POWER segment to put /CBLP-B01-AHU-001-01 in' |
Ideally when laying cables in a segregated branch (a branch with multiple ICLASS segments) the cables are placed in the correct segments. This error is displayed when a segment on the branch that matches the cables ICLASS cannot be found. In this example: the branch /CWAY-POWER02-BUILDING-B01/B1 does not have a POWER ICLASS segment to place the cable /CBLP-B01-AHU-001-01 in. |
|
Wrong Segment - 125, 37 'Layout failed - /CBLP-B01-AHU-001-01 is not in correct segment at /CWAY-POWER02-BUILDING-B01/B1' |
While laying cables and verifying existing laid cables we need to check that the cable is laid in the correct segment of a segregated branch. This error is displayed is this is not the case. In this example: the cable /CBLP-B01-AHU-001-01 is not in the correct segment on the branch /CWAY-POWER02-BUILDING-B01/B1. |
|
Stacking Not Allowed - 125, 39 'Layout failed - Not allowed to stack /CBLP-B01-AHU-001-01' |
While laying cables and verifying existing laid cables we need to check that the cable has been identified as stack able. For example checking the cable itself is allowed to touch other cables, as well as the cables it touches are also allowed to touch other cables. Additionally we need to ensure that there is a cable underneath the cable we are attempting to stack, and that nothing is already stacked there. Should any of the statements be untrue then this error that is returned. In this example: the cable /CBLP-B01-AHU-001-01 is not allowed to stack. |
|
Not Tried Invalid Layout - 125, 38 'Layout failed - Layout could not begin because /CBLP-B01-AHU-001-01 has invalid layout at /CWAY-POWER02-BUILDING-B01/B1' |
Before attempting to lay a cable we must first ensure that the branches have a valid layout. Should a branch be found with an invalid layout, this is the error that is returned. In this example: layout could not begin because the cable /CBLP-B01-AHU-001-01 has an invalid layout on the branch /CWAY-POWER02-BUILDING-B01/B1. |
|
Invalid Setup - 125, 41 'Layout failed - Invalid setup of /CBLP-P1502A-BUNDLE' |
Before attempting to lay a cable bundle it must be first set it up, if this set up fails this error is returned. In this example: the bundle /CBLP-P1502A-BUNDLE has an invalid setup to layout cannot proceed. |
|
Routing Status Mismatch - 125, 42 Bundle error - Cables in /CBLP-P1502A-BUNDLE do not have matching routing statuses' |
Cables that are part of a bundle should always have matching routing statuses, for example: all be routed, all be laid, all be un-routed. If this is not the case, this is the error message that is returned. In this example: the cables that are a part of the bundle /CBLP-P1502A-BUNDLE do not have matching routing statuses. |
|
Used Tray Mismatch - 125, 43 'Bundle error - Cables in /CBLP-P1502A-BUNDLE are not routed along the same trays |
Cables that are a part of a bundle should be routed or routed and laid along the same rectangular cable trays. Should this rule be broken, this error is returned. In this example: cables that are a part of the bundle /CBLP-P1502A-BUNDLE are not routed along the same trays. |
|
Specification Mismatch - 125, 52 'Routing bundle failed - Cables do not have the same SPREF' |
Cables that are a part of a bundle are required to have the same specification, should this rule be broken this is error is returned. |
|
Trefoil Bad Cable Number - 125, 56 'Routing bundle failed - TREFOIL bundle must have 3 cables of type CONDUCTOR' |
A bundle that is of type TREFOIL must have 3 cables of type CONDUCTOR so that the shape of the bundle can be created correctly. Should this rule be broken this error is returned. |
|
Trefoil Conductors Not Touching - 125, 57 'Routing bundle failed - TREFOIL bundle must have 3 cables of type CONDUCTOR with CABLE TOUCHING TRUE' |
A bundle that is of type TREFOIL must have 3 cables of type CONDUCTOR and these CONDUCTORS must have CABLE TOUCHING TRUE so that the shape of the bundle can be created correctly. Should this rule be broken this error is returned. |