Reconnecting Pipes after an Equipment Move
- Last UpdatedFeb 19, 2025
- 1 minute read
Note:
Applicable to Nozzles that have been moved since a Branch was connected to them. Largely
superseded by the DRAG command.
Keywords
RECONNECT
Description
If an Equipment item is moved using an ordinary positioning command, none of the Branches connected to it will move with it. RECONNECT will reconnect all the HEADS and TAILS of Branches connected to an Equipment, moving them to new positions if necessary. Other elements in the Branches are not affected and must be realigned using ordinary routing commands.
Example |
|
|---|---|
|
RECON |
Finds all Nozzle elements which are Offspring of the current element. For each Nozzle, any Branch Head (or Tail) which is connected to it is repositioned at the Nozzle. |
Command Syntax
>-- RECOnnect -->