BENDRADIUS

  • Last UpdatedJul 23, 2025
  • 3 minute read

Function:

Specifies when radii of pulled bends will be shown on drawings and in what units.

Description:

By default, bend radii will be output in distance units for all pulled bends, that is, for all components with SKEYs beginning with PB. The radii of pulled bends are extracted from their RADI attributes. If the RADI attribute is set to zero and the SKEY is of the format PBnD, where n is an integer (for example, PB5D), then the integer will be extracted, multiplied by the pipe diameter, converted to distance units if appropriate, and output as the bend radius.

Bend radii can be shown either in distance units or as multiples of pipe diameters (where pipe diameter is taken as the nominal bore or outside diameter of the pipe). The Atexts associated with the output of bend radii are Atext 337, ‘D BEND RADIUS’ (for bend radii in multiples of pipe diameters), and Atext 338, ‘BEND RADIUS’ (for bend radii in distance units). Setting either of these to be blank causes the entire message to be suppressed, including the actual radius value.

A standard radius for bends can be set using the BENDRADIUS STANDARD command. If a standard radius is set, only bends which have radii different from the standard radius will have their radii shown individually. Both the standard radius and any individual radii will be shown in the same format (that is, in distance units or in pipe diameters).

A note giving the value of the standard radius can be positioned on the sheet using the POSITION command. The usual method is to plot a suitable message, such as:

All pulled bends to be D unless otherwise shown.

as part of an underlay (refer to UNDERLAYPLOTNAME command). Then use the POSITION command to create text giving the actual radius value in the space immediately before the D.

The user can also include a table of bending data on the isometric using the POSITION command (refer to POSITION BENDTABLE command for more details).

Examples:

BENDRAD DEFAULT
BENDRAD

All bend radii are to be shown in current distance units (no standard value).

BENDRAD STAND 200

Bend radii are to be shown in mm, but only if they are not equal to 200mm (assuming the current distance units are mm).

BENDRAD DIAM

Bend radii are to be shown as multiples of pipe diameters.

BENDRAD OUTDIAM

Bend radii are to be shown as multiples of pipe outside diameters.

BENDRAD STAND 5 DIAM

Bend radii are to be shown as multiples of pipe diameters, but only if they do not equal to 5 diameters.

BENDRAD OFF

No bend radii are to be shown on the drawing.

BENDRADIUS STANDARD 5D
POSI BENDRADIUS AT X200 Y50

Standard bend radius note is output at the specified position. Only non-standard radii are output on the isometric. Both the standard note and non-standard radii are output as multiples of the pipe diameter.

BENDRAD STAN 1000
POSI BENDRAD AT X200 Y50

Standard bend radius note is output at the specified position. Only non-standard radii are output on the isometric. Both the standard note and non-standard radii are output in the current distance units (mm or inch).

Command Syntax:

>-- BENDRADius --+-- DEFault -----------------------------.
                 |                                        |
                 |-- STANdard -- value --.                |
                 |                       |                |
                 |-----------------------+-- Diameters ---|
                 |                       |                |
                 |-----------------------+-- Outdiam -----|
                 |                       |                |
                 |                       '----------------|
                 ‘-- OFF ---------------------------------+->

Querying:

Q BENDRADius

Q OPTions

TitleResults for “How to create a CRG?”Also Available in