Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

CROS Symbol Keys

  • Last UpdatedAug 19, 2025
  • 3 minute read

Component Description

SKEY

Plotted Symbol

P-points

Note

Cross - Butt Weld

CRBW

2

Cross - Socket Weld

CRSW

2

Cross - Compression

CRCP

2

Cross - Flanged

CRFL

2

Cross - Screwed

CRSC

2

Cross - Set on

CRSO

1, 2

Cross - Set on Reinforced

CRRF

1,2

Cross - Generic Y-type with variable angle out- and off- legs

X@**

3,4,5

Note:

1

The positions of P3 and P4 along the vertical axis are important for deriving correct cut pipe lengths. The vertical displacements of P3 and P4 are determined by the points at which the offline legs intersect the main line. P0, P1, P2, P3, and P4 will be coincident when the offline leg has the same bore as the main line.

2

The dimensions of all Cross components depend upon plotted leg length. The default plotted leg length is 9mm, but the user can set this to a different value using the LEGLENGTH command. The minimum value the user can set is 6mm.

3

Replace the ** characters in the symbol key with one of the following end condition identifiers:

BW for butt weld

CP for compression

SW for socket weld

FL for flanged

SC for screwed

PL for plain

4

The @ character in the symbol key is replaced automatically by an integer in the range 1 to 4, depending on the relative bore size of the connections, with 1 assigned to the largest bore. It is important to note the bore size if redefining the SKEYS for X1**, X2**, X3** or X4**.

5

Flanged connections on generic Y-type fittings are represented on the isometric on the tube only. This is due to the fact that the y-type fitting is user-definable and flanged representation on the component cannot be enforced. ELBO or BEND Symbol Keys

Related Links