Setting Obstruction & Insulation Representation for Piping Components
- Last UpdatedFeb 19, 2025
- 1 minute read
Keywords
REPRESENTATION OBSTRUCTION INSULATION TRANSLUCENCY
Description
Component Obstructions are often given LEVELS or TUBE and CENTRELINE settings which render them invisible. Setting the Representation of OBST On forces the system to override normal LEVEL and TUBE settings and show all of the primitives, regardless of the other settings.
Setting the Representation of INSU On or Off determines whether or not insulation is shown on primitives.
These have the effect of considering all primitives which have an obstruction level greater than zero and all primitives which are affected by insulation parameters. The graphics display is not updated instantly. Use the REPResentation UPDATE command to make any changes visible.
To avoid obscuring the view in colour-shaded mode, obstruction and/or insulation can be shown as translucent, the degree of translucency being controllable.
Examples |
|---|
|
REPR OBST ON INSU OFF |
|
REPR INSU ON |
|
REPR INSU ON TRANSLUCENCY 25 |
Command Syntax
.------------------------------<---------------.
/ |
>- REPResentation -*- OBSTruction -. |
| | |
‘- INSUlation --+- ON --+------------------------|
| | |
| '- TRANSLucency - value -|
| |
‘- OFF --------------------------+->
Note:
value must be in the range 0‑99: the actual translucency will be set to the nearest of 25, 50, 75 or 87 (99 = transparent;
0 = opaque).
Querying
|
Q REPR |
Lists all Representation settings |
|
Q REPR INSU |
Queries if insulation is ON or OFF |
|
Q REPR OBST |
Queries if OBST is ON or OFF |
|
Q REPR INSU TRANSL |
Queries translucency setting for insulation |