Support Attachment Point Names
- Last UpdatedJul 29, 2025
- 1 minute read
By default, the names of support attachment points (that is, all ATTAs for which the ATTY attribute is unset) are not shown on the isometric plot and their SPREFs (specification references) are used as their item codes.
The user can use the ATTANAME command to display the AVEVA E3D Design names of support ATTAs on the drawings, and to specify whether their AVEVA E3D Design names or their SPREFs are used as their item codes.