GRIL circular diffuser requirements
- Last UpdatedSep 15, 2025
- 1 minute read
This topic describes the specification requirements to create a circular diffuser as a grille type component.
The Generic Type (GTYP) must be set to GRIL on the SCOM hierarchy level. For clarity, it is good practice to also set the GTYP to GRIL on the SECT and CATE levels.
A new component data element CMPD for the GRIL must be created in /AvevaHVACweights area. For example, you can copy an existing CMPD element and name it /SIMDUCT -CLASS-C-GRIL-Weight.
For information about data set requirements that apply for all circular components, refer to Circular component requirements.
P-point requirements
The following p-points are required:
-
P61
-
P62
-
P63
-
P64
Other p-points can also be added if required to help position other GMSE elements in more detail.
For information about P-point requirements that apply for all circular components, refer to Circular component requirements.
The following graphic shows an example of the settings in the HVAC Specification form: