Available Derived P-points for Single Line Representation of GENSEC Elements
- Last UpdatedJun 29, 2023
- 1 minute read
When GENSEC elements are drawn in a Single Line Representation (SLR) style the following derived p-points are available. Refer to Structural Single Line Representation Styles for further information.

|
Point# |
Description |
Direction 1 |
Direction 2 |
|
1001 |
Widget centre. |
Direction of GENSEC. |
Opposite to direction of GENSEC. |
|
1002 |
Right hand side of widget. |
Direction of GENSEC. |
Opposite to direction of GENSEC. |
|
1003 |
Left hand side of widget. |
Direction of GENSEC. |
Opposite to direction of GENSEC. |
|
1004 |
Start of single line. |
Direction of GENSEC. |
Opposite to direction of GENSEC. |
|
1005 |
Central between start of single line and widget. |
Direction of GENSEC. |
Opposite to direction of GENSEC. |
|
1006 |
Start of widget. |
Direction of GENSEC. |
Opposite to direction of GENSEC. |
|
1007 |
End of widget. |
Direction of GENSEC. |
Opposite to direction of GENSEC. |
|
1008 |
Central between widget and end of single line. |
Direction of GENSEC. |
Opposite to direction of GENSEC. |
|
1009 |
End of single line. |
Direction of GENSEC. |
Opposite to direction of GENSEC. |
Note:
All positions and directions are with respect to the GENSEC in its local 3D frame
of reference. In the example image ,p-points 1002 (right) and 1003 (left) swap positions
if the direction of the GENSEC in Model is reversed.