Error Messages

  • Last UpdatedAug 19, 2025
  • 12 minute read

This appendix lists Isodraft error messages that may be output to the screen and message file.

  • Messages generated by Isodraft itself have message numbers beginning with 33.

  • Messages generated by the Isodraw module within Isodraft have message numbers beginning with 35. In most cases, these will arise only when the program limits have been reached, and the user should contact the AVEVA Customer Services Team.

Any other messages that may be output are not described here as they are not specific to Isodraft.

Note: Many of the messages the user will see when using Isodraft result from design or cataloguing errors, not from errors in using Isodraft. For this reason, a data consistency check is strongly advised before Isodraft is used.

The error messages can include variables, presented in this appendix as follows:

integer

an integer

realno

a real (i.e. non-integer) number

name

an item name (general context)

name/refno

a name of an item (or refno if unnamed)

filename

an AVEVA E3D Design filename

text

an alphanumeric character string

(33:1)

Paper size A4 to A0 only allowed

Refer to SIZE command.

(33:2)

ISO 1,2,3,4 only allowed

Refer to ISO command.

(33:3)

AREA must be between 1 & 10

Refer to WASTAGE AREA command.

(33:110)

BAD RETURN FILE

The list of pipes successfully detailed by Isodraw cannot be read.

(33:114)

VALUE MUST BE BETWEEN 1 AND 25

The maximum number of lines permitted in the title block area is 25.

(33:116)

VALUE MUST BE BETWEEN 201 AND 500

The Atext numbers of texts that can be changed by the ATEXT command must be within the specified range. Refer to Recommendations for Importing DXF files from Isodraft into MicroStation for more information on Atexts

(33:121)

PAPER LENGTH must be greater than ZERO

This is self-explanatory.

(33:123)

SPEC REF name gives material code ( text ) longer than max of integer characters

The itemcode derived from the component’s name is longer than the width allowed in the itemcode column in the material list (refer to ITEMCODE (1) command).

(33:124)

VALUE between 1 & 20 only

The identifying number allocated in a KEYS command must be within the specified range.

(33:147)

INST name/refno is not named

Itemcodes for instruments are currently defined as AVEVA E3D Design names (probably by default) and an instrument has been found without a name.

(33:149)

SYSTEM ERROR

Unable to scan pipe network

Check data consistency report and flow directions at branch connections.

There is a design inconsistency that prevents Isodraft from detailing the specified pipeline. Run a data consistency check to find probable sources of error. In some cases, this error may be produced by a configuration, which is legal but which cannot currently be scanned by Isodraft. This problem can usually be resolved by splitting the pipe into more branches.

(33:150)

BAD NAME/REF

A name or reference specified for detailing cannot be accessed.

(33:151)

Too many items in DETAIL list

The Detail list cannot contain more than 100 items.

(33:152)

Can’t remove NAME/REF

A name or reference specified in a Remove list cannot be accessed. In particular, note that World must not occur in a Remove list.

(33:153)

Too many items in REMOVE list

The Remove list cannot contain more than 100 items.

(33:155)

The DETAIL list is empty

Either there are no items in the Add list or the items specified in the Remove list have completely cancelled out those specified in the Add list, leaving nothing to be detailed.

(33:156)

PLOT FILE NAME/PREFIX or TERM have not been specified

The output destination (terminal or named file) must be specified before Isodraft can detail anything.

(33:157)

NO PIPES HAVE BEEN PROCESSED SUCCESSFULLY

Isodraft has failed to detail any pipes. The reasons may be suggested by other error messages generated during the detailing processes.

(33:158)

MORE THAN 100 BRANCHES IN PIPE name/refno

Isodraft cannot cope with more than 100 branches in one pipeline.

(33:159)

NO BRANCHES IN PIPE name/refno

This is self-explanatory.

(33:160)

name/refno will not be detailed

The specified Pipe or Branch cannot be detailed by Isodraft. The reason may be found in another message or a data consistency report.

(33:162)

HEAD & TAIL refs of BRANCH name/refno refer to the same component but head & tail positions are not close enough to that component

There is an error in the identified branch, which has both ends connected to the component. This should not normally occur.

(33:163)

HEAD & TAIL refs of BRANCH name/refno refer to the same component and head & tail positions are the same

There is an error in the identified branch, which has both ends connected to the component. This should not normally occur.

(33:164)

Component name/refno refers to a BRANCH ( name/refno ) which does not refer back to it

There is an inconsistency between the connection attribute of the component and the branch to which it refers. For example:

(33:165)

The HEAD of name/refno is connected to name/refno but the positions are not the same

(33:166)

The TAIL of name/refno is connected to name/refno but the positions are not the same

There is an inconsistency between the HPOS or TPOS attribute of the branch and the p-point of the component to which it should be attached.

(33:167)

ELEMENT name/refno is not a piping component

An element found while detailing a pipe is not of an appropriate type.

(33:168)

Cannot find FLANGE to match PPOINT integer of name/refno

The connection reference on the given p-point needs to be accessed to determine the bolting requirements. This message means either that the connection reference is unset or invalid, or that a component of type FLAN cannot be found on that connection.

(33:169)

Cannot find end of WAFER at name/refno

The other end of the wafer fitting at the specified location cannot be found. Connection types commencing with W must be used in pairs.

(33:170)

BOLTING BRANCH Table full

(33:171)

BOLTING MULTIWAY COMPONENT Table full

These tables keep account of those items which have already been accessed for bolting requirements. The limits are 100 items in the Branch Table and 200 items in the Multiway Component Table.

(33:172)

No non-standard BOLT lengths for SBOLT name/refno

LENGTH is realno

(33:173)

No long enough non-standard BOLT lengths for name/refno

Refer to Catalog Requirements.

(33:174)

No SPCOM for name/refno

The item specified has no component specification from which bolting requirements (the BLTREF attribute) can be derived. Refer to Catalog Requirements.

(33:175)

No BOLTS for SPCOM name/refno

The SPCOM for the specified item does not have its BLTREF attribute set and so its bolting requirements cannot be determined. Refer to Catalog Requirements.

(33:176)

Invalid SPCOM name/refno for component, or tube connected to, name/refno

A component, or the implied tube connected directly to it, does not have a valid specification reference (SPRE or LSTU). Check the data consistency report.

(33:177)

Cannot get DETAIL info. on SPCOM name/refno

(33:178)

Cannot get MATXT info. on SPCOM name/refno

These indicate possible cataloguing errors. The SPCOMs specified do not have the appropriate attributes set for the data needed by Isodraft. Refer to Catalog Requirements.

(33:179)

Reference datum name/refno is unnamed

No text will be shown for the reference dimension on the isometric.

(33:180)

PWAST attribute from SPCOM name/refno out of range 0.00 - 100.0

The wastage allowance attribute must be set to a percentage figure between 0 and 100%. Refer to WASTAGE AREA command.

(33:181)

BOLT TABLE FULL

The number of different bolts that can be processed in a single pipe is limited to 1000.

(33:182)

name/refno connected to name/refno but not the other way round

(33:183)

name/refno not close enough to name/refno

(33:184)

ARRIVE or LEAVE PPOINT greater than 4

Isodraft can only deal with 4-way components whose arrive or leave p-points are not greater than 4.

(33:185)

Multi-way component name/refno is not connected where expected

(33:187)

Both legs of name/refno refer to the same BRANCH but positions are not the same.

(33:188)

Both legs of name/refno refer to the same BRANCH and positions are the same.

(33:189)

One leg of name/refno is connected to name/refno but the positions are not the same.

Errors (33:182) to (33:189) all indicate possible errors in the DESIGN databases. Check the data consistency report and correct errors using a Model module.

(33:190)

CANNOT OPEN OPTIONS WORK FILE : ERROR integer

(33:191)

CANNOT OPEN MESSAGE FILE : ERROR integer

(33:192)

OPTIONS STATE IS LOST

OPTIONS RESTORED TO DEFAULTS

These indicate system filing errors, possibly due to a disc overflow. In most cases, further explanatory messages will be output.

(33:193)

MESSAGE FILE NOT SET

A file for output messages must be specified before Isodraft can begin any detailing. Refer to MESSAGEFILENAME command.

(33:195)

BRANCH name/refno is not in the network

A pipe must have all its branches connected to each other in order to be detailed. The branch specified does not appear to be connected in this way.

(33:196)

name/refno has already been detailed

The Pipe or Branch specified has its Detail Flag set to TRUE. It may be detailed by using the MARK IGNORE ON option, or by resetting the DETA attribute to FALSE in an Model module.

(33:197)

SYSTEM WARNING - MATERIAL NAME TABLE OVERFLOW - MAX integer NAMES

This could occur on isometrics which incorporate a very large number of different items. It could result in items with the same itemcodes, but with different suffixes, being treated as different items.

(33:198)

ATTACHMENT POINT name/refno HAS NO STEXT

An ATTA being used as a comment (ATTY set to CCCC or CCNN) has no text stored in its STEXT attribute.

(33:199)

ERROR IN DETERMINING BOLTING FOR name/refno

Refer to Bolting for information on the cataloguing requirements for bolts.

(33:200)

Unable to access PIPE SPEC name/refno

A pipe specification referenced by a pipe specified in a detailing command is not accessible in the current MDB.

(33:203)

BAD CONNECTION TO name/refno

This suggests a possible error in the HREF or TREF of a branch. Check the data consistency report and rectify errors using an Model module.

(33:252)

Unable to locate text text within itemcode

The locating text specified in a BOLT LENGTH ITEM INSERT AT ‘text’ command (refer to BOLTING command) cannot be found in the itemcode for a bolt. Isodraft will use the default format for this bolt in the itemcode list and outputs this message for information only.

(33:267)

name/refno - Illegal or Inaccessible Reference Datum point

The reference dimension is pointing to an incorrect or non-existent element.

(33:268)

Reference datum name/refno - Orientation has been modified to

prevent Doubleback Dimension error

The reference dimension requested for a Structure is parallel to the centreline. A reasonable orientation has been chosen instead.

(33:269)

Dimension omitted for Reference datum name/refno - Doubleback Dimension

The reference dimension requested for a Piping component or Section is parallel to the centreline.

(33:299)

Illegal scale factor found for line flow arrow - default scale 8 used

The scale factor for in-line flow arrows must be in the range 5 to 15 inclusive.

(33:331)

Illegal HREF connection on BRAN name/refno

(33:332)

Illegal TREF connection on BRAN name/refno

The Head or Tail Reference of the Branch being detailed is invalid. It may have been deleted, or it may be in a DB which is not current in the MDB.

(33:338)

User defined symbol library has not been specified

The user have tried to define a symbol without first specifying a symbol library file in which to store the definition. Refer to Symbol Keys.

(33:340)

Limit of integer user defined symbols exceeded

(33:341)

Symbol key text rejected

The user has tried to define more symbols than the current maximum limit of 300. The specified symbol will not be added to the symbol library. Refer to Symbol Keys.

(33:343)

Error in updating symbol library

An existing symbol file cannot be overwritten. Check that the user has sufficient access rights.

(33:345)

Unable to create new symbol library text

A new symbol file cannot be created. Check that the user has sufficient access rights.

(33:346)

Error reading symbol library text

An existing symbol file cannot be read. Check that the user has sufficient access rights.

(33:347)

Unable to locate key text in symbol library

The specified SKEY cannot be found in the current symbol library.

(33:348)

Row number integer is outside the range 1-999

(33:349)

Table number integer is outside the range 1-999

The user has exceeded the limits of table definition for user-positioned text. Refer to ATEXT command.

(33:350)

Limit of integer user positional text records exceeded

The user has tried to position more than the current maximum limit of 400 text fields. Refer to ATEXT command.

(33:351)

Character size integer exceeds maximum limit of 99

The user has specified a character height greater than the maximum limit of 99mm. Refer to ATEXT command.

(33:361)

Option number integer is outside the allowed range 1-140

Debug options must lie within the range 1-140.

(33:363)

Balloon size integer is outside the allowed range 1-5

The user has specified an instrument balloon size outside the permitted range of 1-5 character widths.

(33:365)

The no of components :- integer is outside the allowed range 1-50

The user can only turn off fallskew boxes for lengths of pipeline containing no more than 50 components. Refer to FALLSKEWS command.

(33:368)

SPOOLNumbers must be positioned with table parameters

User-positioned text for spool numbers must include X and Y offsets within its definition to form a tabular layout. Refer to POSITION command.

(33:386)

Bend radius outside allowable range 0 to 50 D

The permitted range for standard bend radii is 0-50 pipe diameters.

(33:387)

Illegal value for bend radius

The user can not specify a standard bend radius of less than 1mm.

(33:399)

Maximum of 20 nested PCOM tappings exceeded

Tapping legs off PCOMs or SHUs can themselves contain PCOMs or SHUs with tapping legs, up to a maximum limit of 20 levels of nesting.

(33:407)

Cannot detail at branch level for system iso

Detailing at Branch level is restricted to single pipe isometrics. System isometrics must include complete pipes.

(33:408)

Plottingscale limits (50-100%) exceeded - reset to 100

Note: The plotting scale is limited to a reduction to a minimum of half size. Magnification is not permitted. The scaling factor has been reset automatically to 100%.

Note: The following error messages are generated during the operation of Isodraw. Those numbered (35:10xx) relate to the ISODAT program and those numbered (35:20xx) relate to the ISOPLOT program.

Note: Refer to the AVEVA E3D Design Customer Support Department for advice if the user has unexplained errors at this stage of Isodraft’s operations.

(33:890)

ANCILLARY is not positioned on the leave tube centre line

An Support Ancillary is not aligned to the centre line of the Pipe. Refer to Align Supports with Pipe for further information.

(35:1001)

OVER 200 ALTERNATIVE TEXT RECS FOLLOWING DATA IGNORED

(35:1002)

MORE THAN 200 TEXT RECORDS - DEFAULT TABLE USED

The maximum number of non-standard text phrases that may be used at one time is 200 (refer to ATEXT command).

(35:1004)

FITTING NOT FOUND - DEFAULT SHAPE USED

A specified SKEY is not recognised. The relevant component will be indicated on the isometric drawing by the default rectangle symbol. Refer to Symbol Keys for further information.

(35:1006)

to

(35:1014)

OVERFLOW IN DATA - PIPELINE REJECTED

(message number depends on reason for overflow - see below)

This is a fatal error; the isometric will not be plotted.

(35:1015)

INVALID ITEM/DESCRIPTION POINTER

(35:1016)

ITEM CODE WIDTH ERROR - APPENDED TEXT LOST

An itemcode contains more characters than the specified column width in the material list (refer to ITEMCODE (1) command).

(35:1017)

OVERFLOW IN DATA - CHECK DIMENSIONS

(35:1018)

NO FITTING DETAILS EXIST FOR FITTING CODE

(35:1019)

FITTINGS OVERLAP WHICH CANNOT BE CUT BACK

(35:1020)

INSUFFICIENT LENGTH ON OVERLAPPING FITTINGS TO ALLOW CUTBACK

(35:1021)

RUN ABORTED

THE WIDTH OR HEIGHT (EXCLUDING BORDERS, MATERIAL LIST ETC) IS LESS THAN 50MM. THIS IS NOT ENOUGH ROOM FOR THE ISOMETRIC

The layout specified for the drawing sheet does not leave enough room for the isometric drawing itself. The drawing will not therefore be plotted. Refer to FILE, SIZE and STACKINGARRANGEMENT commands.

(35:1022)

THE MATERIAL CODE IS TOO WIDE AND HAS BEEN CHANGED FROM ... TO ...

(35:1023)

THE TOTAL NUMBER OF ALLOWED CHARACTERS (3,900) IN FREE MESSAGES HAS BEEN EXCEEDED

(35:1024)

THE NUMBER OF FREE MESSAGES (50) HAS BEEN EXCEEDED

(35:1025)

THE NUMBER OF CHARACTERS IN MESSAGE EXCEED (300)

THE (LAST) MESSAGE BEGAN WITH ...

(35:1084)

Warning - Support shape not found

(35:1100)

Error - Unable to position ref.dimension using coordinates given

- Ref dimension record co-ords are val val val

- Ref dimension not shown on drawing

(35:1105)

Warning - Reference Dimension key " " not found - Default line shown

An invalid or blank SKEY has been used for a reference dimension. Refer to Design Requirements for further information.

(35:2001)

DRAWING DELETED

(35:2003)

WELD NUMBERS HAVE CAUSED DATA OVERFLOW

(35:2004)

INPUT DATA OVERFLOW

(35:2005)

WARNING TEE OFF TEE >4 DEEP

(35:2007)

TEE IN SKEW

(35:2008)

DATA FAULT SKEW

(35:2009)

SKEW WITH NO CONTENTS

(35:2010)

FITTING WITH OFFSET NOT IN LINE WITH PIPE

(35:2011)

ANGLE FAIL

(35:2012)

DATA FAULT

(35:2013)

UP DOWN

(35:2014)

EAST WEST

(35:2015)

NORTH SOUTH

(35:2016)

DATA OVERFLOW, DRAWING REJECTED

(35:2017)

MESSAGE FAIL

(35:2018)

SHAPE FAIL

(35:2020)

TOO MANY COORDINATES IN FITTINGS

(35:2021)

TOO MANY FITTINGS

(35:2023)

WARNING, PAPER SIZE >A0 OR AD - THIS MAY PRODUCE UNACCEPTABLE RESULTS

Isodraft does not recognize standard paper sizes larger than A0 or E. Larger sheet sizes can be specified by using the HEIGHT and WIDTH options. Refer to SIZE command.

(35:2024)

REJECTED, TOO MUCH DATA, TRY SMALLER SPLIT

(35:2025)

... CHECK

(35:2026)

... FAIL

(35:2027)

... PLOTTED

(35:2028)

... NOT PLOTTED

(35:2029)

... DRG.

These are used in progress summaries in the message file.

(35:2030)

WARNING PLOTFILE NUMBER HAS REACHED 999

NEXT PLOTFILE WILL OVERWRITE ...001

PLOT file names are suffixed with a three-digit number to avoid ambiguity. This limits the number of different PLOT files with the same basic file name to 999. Refer to FILE command.

(35:2031)

THE FOLLOWING DRAWINGS ARE IN PLOTFILE ...

(35:2035)

READY FOR NEXT DRAWING. HIT RETURN TO GO

This message appears on screen between plots when more than one drawing is to be output to a graphics terminal.

(35:2036)

THE FOLLOWING DRAWINGS WERE SENT TO THE TERMINAL

(35:2037)

ERROR OPENING UNDERLAY PLOTFILE

(35:2038)

ERROR READING PLOTFILE

(35:2039)

PLOTFILE INCOMPATIBLE PAPER SIZE

(35:2040)

BAD PLOT CODE - PLOTFILE PROBABLY CORRUPT

(35:2041)

THE SCHEMA PLOTFILE OPTION HAS BEEN SWITCHED OFF

(35:2042)

SPECIFIED PLOTFILE LENGTH ...

(35:2043)

... IS LESS THAN DRAWING LENGTH

(35:2044)

PLOTFILE LENGTH HAS BEEN INCREASED TO ...