TAPE circular requirements

  • Last UpdatedApr 14, 2025
  • 2 minute read

This topic describes the specification requirements for circular taper (TAPE) components.

Parameter description requirements

  • Parameter #1 = Width of arrive

  • Parameter #2 = Width of leave

Data set requirements

For information about data set requirements that apply for all circular components, refer to Circular component requirements.

The following requirements are in addition to the data references that are created for parameters.

KEY

Type

Description

Default ( /Expression **)

SHAP

Null

Duct shape

‘CIRC’

AARR

Distance

Width of arrive

PARA[1 ]

BARR

Distance

Height of arrive

0

ALEA

Distance

Width of leave

PARA[2 ]

BLEA

Distance

Height of leave

0

** Where the Default value is set to a parameter, the Expression value must be set to the same parameter. This is applicable for all component types.

P-point requirements

For information about P-point requirements that apply for all circular components, refer to Circular component requirements.

P-point P2 is PTMI type because it is offset from the Z axis.

The following table shows the additional required P-points:

Type

Connection Type (PCON)

Bore (PBOR)

Axis Direction (PAXI)

PZ Axis (PZAXI)

Point Width (PWID)

PDShape attribute

AllAngle attribute

1

PTAX

CIRC

(RPRO AARR + RPRO BARR)

-Z

Y

(RPRO AARR + RPRO BARR)

CIRC

1

2

PTMI

CIRC

(RPRO ALEA + RPRO BLEA)

Z

Y

(RPRO ALEA + RPRO BLEA)

CIRC

1

61

PTMI

0

0

Y

unset

unset

0

unset

62

PTMI

0

0

Y

unset

unset

0

unset

63

PTMI

0

0

Y

unset

unset

0

unset

64

PTMI

0

0

Y

unset

unset

0

unset

The P-points are arranged as shown in the following graphic:

Specification requirements

The following specification headings are required:

  • Type (TYPE)

  • Duct Shape (PSHA)

  • Duct Width 1 (PWID1)

  • Duct Height 1 (PHEI1) = 0

  • Duct Width 2 (PWID2)

  • Duct Height 2 (PHEI2) = 0

Specific Type (STYP) is used to differentiate between eccentric and concentric. This could simply have values of ECC and CONC.

The order of Duct Width 1, Duct Height 1, Duct Width 2, Duct Height 2 does not affect selection and use in the Model module.

In This Topic