XHBSCLA
- Last UpdatedFeb 11, 2025
- 1 minute read
Arguments
|
1 |
SCLA STYP |
|---|---|
|
2 |
Any other selectors (quoted if using TANS) |
|
3 |
Fit flag. True if SCLA is to be fitted into the available space. |
|
4 |
P-point to orientate towards previous component. The subroutine will attempt to align the PA/PL, but if this in insufficient, then it will use this p-point. Default orientation is determined by argument 5. |
|
5 |
Default orientation: |
|
TUBE: Pipe flow direction |
|
|
STEEL: Steel direction (can be SCTN Y or X direction depending on hanger Tail connection type) |
|
|
6 |
Any other selectors (quoted if using TANS): |
|
INSPEC: Select from current HSPEC |
|
|
PSPEC: Select from attached pipe PSPEC |
|
|
<gid>: Select from explicit specification |
Globals used
None
Globals set
|
!!CDSNHB.RTOVAL1 |
Derived RTO value at P1 end |
|
!!CDSNHB.RTOVAL2 |
Derived RTO value at P2 end |