Arguments

1

SCLA STYP

2

Any other selectors (quoted if using TANS)

3

Fit flag. True if SCLA is to be fitted into the available space.

4

P-point to orientate towards previous component. The subroutine will attempt to align the PA/PL, but if this in insufficient, then it will use this p-point. Default orientation is determined by argument 5.

5

Default orientation:

TUBE: Pipe flow direction

STEEL: Steel direction (can be SCTN Y or X direction depending on hanger Tail connection type)

6

Any other selectors (quoted if using TANS):

INSPEC: Select from current HSPEC

PSPEC: Select from attached pipe PSPEC

<gid>: Select from explicit specification

Globals used

None

Globals set

!!CDSNHB.RTOVAL1

Derived RTO value at P1 end

!!CDSNHB.RTOVAL2

Derived RTO value at P2 end