Specifying Pipe End Conditions for use by Isodraft
- Last UpdatedJan 13, 2023
- 1 minute read
The Isodraft Connection Key (CKEY) attribute is used by Isodraft to determine what type of connection is used to join two elements (for example: Butt weld, Screwed and so on). Refer the Connection Compatibility Tables for further information, to edit the CKey refer to Keys for further information.
Once an entry has been populated in the Connections grid, the Isodraft Connection Key drop-down, located at the bottom of the Connections Compatibility Table window, becomes active. By default Unset is selected, if this is left as the default it is assumed to be plain connection.
Select the pipe end conditions, from the drop-down list:
-
BW for butt weld
-
CP for compression
-
FL for flange
-
PL for plain
-
SC for screwed
-
SW for socket weld
-
Unset