Ignoring Clashes at Steelwork Junctions
- Last UpdatedFeb 19, 2025
- 1 minute read
Keywords
INCLUDE IGNORE CONNECTIONS ALL WITH SPECIFICATIONS
Description
This facility allows the user to control checking at steelwork junctions. (Clashes between sections and attached joints etc. are ignored automatically.)
Frequently, the user may wish to leave end preparations at steelwork joints until late in the design process. This option can inhibit clash reporting using the commands described here.
Examples |
|
|---|---|
|
INCLUDE CONNECTIONS |
Includes all steelwork connections during subsequent clash checking. |
|
IGNORE CONNECTIONS |
Ignores steelwork connections during checking. |
|
IGNORE CONNECTIONS WITH SPECIFICATIONS |
Ignores only those connections which have specifications. |
Command Syntax
>-- INClude -- CONnections -->
>-- IGNore --+-- ALL --.
| |
‘---------+-- CONnections -->
>-- IGNore -- CONnections -- WIth -- SPEcifications -->