Clash Check the CE (Current Element)​.

  • Last UpdatedMay 26, 2023
  • 1 minute read

This procedure is available to users as defined by the administrator, refer to Discipline for further information.

Note:
The CE must be at or below a Group Element Type, the group element is the element that will be clash checked.

From the AVEVA Clash Manager window, select Tools then Clash Check CE to initiate the Clash Check CE process.

The first time the Clash Check CE process in a particular MDB is initiated, a personal clash set titled Userid/MDB is created and displayed on the AVEVA Clash Manager - Clash Set window.

Update the default details, as required, refer to Personal Clash Set for further information. When the details are as required, click OK.

Note:
Userid is the user’s windows UserId and not the userid used to access the 3D model.

The personal clash set is run, the clashes can be viewed using the Clash Report. Refer to Clash Report for further information.

Note:
If a clash is resolved through deleting or relocating one or both of the clashing elements, records of the clash will become dormant when any clash set referencing the elements is re-run.