Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

Locating a Pin by Copying or Connecting

  • Last UpdatedFeb 19, 2025
  • 1 minute read

Keywords

PIN COPY CONNECT

Description

A pin’s position and direction can be set by copying or connecting to any other p-point or pin, the only difference being that the CONNECT operation orientates the specified pin in the opposite direction.

Examples

PIN 5 C0PY IDP @

Pin 5 will be placed at the same position and orientation as the p-point or pin hit by the cursor.

PIN 5 CONNECT TO PH

Pin 5 will be placed at the Branch Head, but pointing in the opposite direction to HDIR (Head direction). This command must be given at BRANCH level. Pin 5 can be an existing pin or a new one.

Command Syntax

>-- PIn integer --+-- Copy --------------.
                  |                      |
                  ‘-- CONnect --+-- TO --|
                                |        |
                                ‘--------+-- <marke> -->

Querying

>-- Q PIN integer --+-- POSition ---.
                    |               |
                    ‘-- DIRection --+-- WRT --.
                                    |         |
                                    |-- IN ---+--  <gid> --.
                                    |                      |
                                    ‘----------------------+-->

In This Topic
Related Links
TitleResults for “How to create a CRG?”Also Available in