Size
- Last UpdatedMay 09, 2023
- 3 minute read

The Size tab allows the design parameters for a specific bore size to be modified. The displayed design parameters correspond to the selected table row on the Parameters tab.
The design parameter descriptions that display on the Size (and Parameter) tabs are taken from the DTREF of the SCOM. The SCOM can be located in the hierarchy. For example, for an AT01, all the SCOM are collected for /ATTA-AT01.

Where the CATE cannot be found, the design parameter descriptions display as unset, and the message Cannot collect SCOM DBREFS and get descriptions displays on the status bar. If the CATE is found, but one or more design parameter descriptions are unset, it displays as unset.
Preview
The preview displays a graphical view of the selected ancillary bore. Updates to values in the list of parameters on the left hand side of the window are updated in real time in the preview.
Right-click the Eye on the top right hand side of the preview to display a drop-down menu.

|
Display Axes |
Select the option to display the axis in the preview.
|
|
Display Ppoints |
Select the option to display Ppoints in the preview.
|
|
Display Reflection |
Select the option to display reflective lighting in the preview.
|
|
Draw Holes |
Select the option to display holes in the preview.
|
|
Draw Obstruction |
Select the option to display obstruction values in the preview.
|
|
Capture screenshot |
|
|
Single |
Creates a screenshot of the of the currently displayed preview. The screenshot is saved as a *.png file. Use the Save screenshot window to navigate to the desired location and name the saved file. |
|
All sizes |
Creates a screenshot of the preview for all nominal bore sizes. The screenshots are saved as *.png files. Use the Browse For Folder window to navigate to the desired location for the saved files. The files are autonamed using a combination of the support standard and bore size. |
All modifications are reflected in the relevant table on the Parameters tab.
On returning to the Parameters tab, all modifications can be viewed. If the modifications are satisfactory, all the changes can be applied to the database by clicking Apply.