Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

MESH flat oval requirements

  • Last UpdatedAug 25, 2025
  • 2 minute read

This topic describes the specification requirements for flat oval mesh (MESH) components.

Note:
For implied ducting components to be shown in the Model module, the allowable angle AllAngle for the component connected to a mesh component must be set to 180.

Parameter description requirements

  • Parameter #1 = Width of arrive

  • Parameter #2 = Height of leave

    Note:
    Where the Arrive and Leave are different sizes, additional parameters are required. Normally the Width and Height parameters can be used for both Arrive and Leave sizes.

Data set requirements

For information about data set requirements that apply for all flat oval components, refer to Flat oval component requirements.

The following requirements are in addition to the data references that are created for parameters.

KEY

Type

Description

Default ( /Expression **)

SHAP

Expression

Duct shape

‘OVAL’

AARR

Distance

Width of arrive

PARA[1 ]

BARR

Distance

Height of arrive

PARA[2 ]

ALEA

Distance

Width of leave

PARA[1 ]

BLEA

Distance

Height of leave

PARA[2 ]

LENG

Distance

Length of subcomponent in line of duct

Not available

** Where the Default value is set to a parameter, the Expression value must be set to the same parameter. This is applicable for all component types.

P-point requirements

For information about P-point requirements that apply for all flat oval components, refer to Flat oval component requirements.

The following table shows the additional required P-points:

Type

Connection Type (PCON)

Bore (PBOR)

Axis Direction (PAXI)

PZ Axis (PZAXI)

Point Width (PWID)

Point Height (PHEI)

PDShape attribute

AllAngle attribute

1

PTAX

OVAL

(RPRO AARR + RPRO BARR)

-Z

Y

RPRO AARR

RPRO BARR

OVAL

180

2

PTAX

OPEN

0

Z

Y

unset

unset

0

unset

61

PTMI

0

0

Y

unset

unset

unset

0

unset

62

PTMI

0

0

Y

unset

unset

unset

0

unset

63

PTMI

0

0

Y

unset

unset

unset

0

unset

64

PTMI

0

0

Y

unset

unset

unset

0

unset

The P-points are arranged as shown in the following graphic:

Specification requirements

The following specification headings are required:

  • Type (TYPE)

  • Duct Shape (PSHA)

  • Duct Width (PWID)

  • Duct Height (PHEI)

Specific Type (STYP) can be used to differentiate between different types of mesh.