Multi Bolt Table

  • Last UpdatedJan 13, 2023
  • 1 minute read

This functionality can now be now referred to as the Bolt Reference Array on a component, if the flange rating on each end of a Flange Component is different.

For example: a Pressure Relief Valve (PSV) or a Pressure Reducing Valve (PRV), the inlet may be 100NB 300# and the outlet 150NB 150# so the Bolts size, count and length would be different.

Multiple Bolt Lists (MBLI) are administrative elements used to group together Multiple Bolt Elements (MBOLT). Use the Multiple Bolting tab of the Bolt Table Utilities window to add or delete an administrative MBLI element. The Bolt Name field is populated by default with the Unset.

Note:
The Bolt Name cannot contain spaces.

The functionality to add or delete an MBLI element is identical to that for an BLIST element, refer to Single Bolt Table for further information.