Please ensure Javascript is enabled for purposes of website accessibility
Powered by Zoomin Software. For more details please contactZoomin

AVEVA™ Unified Engineering

Checker Examples

  • Last UpdatedJan 23, 2023
  • 4 minute read

Checking a panel boundary for zero length edges and missing vertices. The comments in the Programmable Macros Language (PML) code describe the operations being performed.

------------------------------------------------------------------------

-- Description:

-- Checks for bad definition of panel boundary vertices:

-- Zero length edge; Less than three vertices; Panel loop not found

------------------------------------------------------------------------

define function !!EdgeCheck(!PanelRef is DBREF, !Check is CHKDEFINITION ) is CHKRETURN

-- Initialise Variables

!Result = object CHKRETURN()

!Result.Passed = true

!Result.Messages.clear()

-- Get panel loop element - error if it does not exist

!PloopRef = ( PLOOP 1 OF $!PanelRef )

Handle any

!Result.Passed = false

!Result.Messages.append('No Panel Loop Found')

return !Result

endhandle

-- get array of vertices belonging to the panel boundary

VAR !Vertices COLLECT ALL PAVE FOR $!PloopRef

!NumberOfVerts = !Vertices.size()

-- Check that there are at least three vertices

if(!Vertices.size() lt 3) then

!Result.Passed = false

!Result.Messages.append('Only ' & !Vertices.size() & ' Vertices')

return !Result

endif

-- Add first vertex to the end to close the loop

!Vertices.append(!Vertices[1])

-- Loop through vertices and check for zero length edge

do !IndexVerts to !NumberOfVerts

-- get address and position of this vertex and next vertex

!Vertex = !Vertices[!IndexVerts].dbref()

!NextVertex = !Vertices[!IndexVerts + 1].dbref()

!VertexPos = !Vertex.Pos

!NextVertexPos = !NextVertex.Pos

-- calculate distance between vertices & test for less than 0.01mm tolerance

VAR !Dist CONSTRUCT DIST $!VertexPos TO $!NextVertexPos

if(!Dist.real() lt 0.01mm) then

!Result.Passed = false

!Result.Messages.append('Zero length edge: Vertex ' & !IndexVerts.string())

skip

endif

enddo

-- Return Data

return !Result

endfunction

The following is a sample report generated by running the preceding panel boundary check:

Check Report File

Created By : M.Barlow

Date : 10 Oct 97

Checks Performed

Class : Steelwork

Group : Panels

[1] Check Panel Boundary

Summary of Checks

Elements passed all tests : 8

Elements failed on or more tests : 4

Total : 12

Elements that have passed all checks : 8

DEVTEST-C22001-P00001

DEVTEST-C22001-P00002

DEVTEST-C22001-P00003

DEVTEST-C22001-P00004

DEVTEST-C22001-P00005

DEVTEST-C22001-P00006

DEVTEST-C22001-P00007

DEVTEST-C22001-P00008

Elements that have failed one or more checks: 4

Element: PANEL 1 of FRMWORK /DEVTEST-C22001

Check Panel Boundary - No Panel Loop Found

Element: PANEL 2 of FRMWORK /DEVTEST-C22001

Check Panel Boundary - Only 1 Vertices

Element: PANEL 3 of FRMWORK /DEVTEST-C22001

Check Panel Boundary - Zero length edge: Vertex 2

Element: PANEL 8 of FRMWORK /DEVTEST-C22001

Check Panel Boundary - No Panel Loop Found

End of Check Report File

Checking the names of PANE, SCTN, FRMW and SBFR elements for primary steel ZONES (with FUNC ‘PS’). This example checks a panel boundary for zero length edges and missing vertices. The comments in the PML code describe the operations being performed.

------------------------------------------------------------------------

-- Description:

-- Checks that the first two letters of primary steel element names are

-- the same as the first two letters of the Production Number of that

-- ZONE. The Production Number is stored in UDA :PRODNO. A Zone containing

-- primary steel has its FUNC attribute set to 'PS'. Errors tested:

-- Production Number UDA not set

-- Production Number UDA incorrect (less than two letters)

-- Steelwork element not named

-- Name of <item full name> does not begin with <first 2 letters of :PRODNO>

------------------------------------------------------------------------

define function !!PSNameCheck (!ItemRef is DBREF, !Check is CHKDEFINITION ) is CHKRETURN

-- Initialise Variables

!Result = object CHKRETURN()

!Result.Passed = true

!Result.Messages.clear()

-- Get Production Number and check that it is set

!ZoneRef = ( ZONE OF $!ItemRef )

!ProductionNumber = !ZoneRef.attribute(':PRODNO')

if ( !ProductionNumber.empty() ) then

!Result.Passed = false

!Result.Messages.append('Production Number not set for ' & !ZoneRef.flnn)

return !Result

endif

-- Check that production number has at least two characters

if ( !ProductionNumber.length() lt 2 ) then

!Result.Passed = false

!Result.Messages.append('Production Number incorrect for ' & !ZoneRef.flnn)

return !Result

endif

-- Get first two characters of the production number

!ProdCode = !ProductionNumber.substring(1,2)

-- Get name of steel element

!Name = !ItemRef.Name

-- Test for unset name - First character will be '='

if(!Name.substring(1,1) eq '=') then

!Result.Passed = false

!Result.Messages.append(!ItemRef.Type & ' not named ')

return !Result

endif

-- Test for first two letters of Production number = first two letters of name

if( !Name.substring(2,2) neq !ProdCode ) then

!Result.Passed = false

!Result.Messages.append( !ItemRef.Type & ' name does not begin with ' & !ProdCode )

endif

-- Return Data

return !Result

endfunction

The following is a sample report generated by running the preceding panel name check:

Check Report File

Created By : M.Barlow

Date : 9 Oct 97

Checks Performed

Class : Steelwork

Group : Administration

[1] Check Primary Steelwork Names

Summary of Checks

Elements passed all tests : 13

Elements failed one or more tests : 5

Total : 18

Elements that have passed all checks : 13

PA-C22001-P00002

PA-C22001-S00001

PA-C22001-P00003

PA-C22001-S00003

PA-C22001-S00004

PA-C22001-S00005

PA-C22001-S00006

PA-C22001-S00007

PA-C22001-S00008

PA-C22001-S00009

PA-C22001-P00005

PA-C22001-P00006

PA-C22001-P00007

Elements that have failed one or more checks: 5

Element: DEVTEST-C22001

Check Primary Steelwork Names - FRMW name does not begin with PA

Element: DEVTEST-C22001-P00001

Check Primary Steelwork Names - PANE name does not begin with PA

Element: DEVTEST-C22001-S00002

Check Primary Steelwork Names - SCTN name does not begin with PA

Element: DEVTEST-C22001-P00004

Check Primary Steelwork Names - PANE name does not begin with PA

Element: PANEL 5 of FRMWORK /DEVTEST-C22001

Check Primary Steelwork Names - PANE not named

End of Check Report File